 8 Bit Microcontroller
TLCS-870/C Series
TMP86C845UG
TMP86C845UG
The information contained herein is subject to change without notice. 021023 _ D TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc. 021023_A The Toshiba products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These Toshiba products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc. Unintended Usage of Toshiba products listed in this document shall be made at the customer's own risk. 021023_B The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. 060106_Q The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others. 021023_C The products described in this document may include products subject to the foreign exchange and foreign trade laws. 021023_F For a discussion of how the reliability of microcontrollers can be predicted, please refer to Section 1.3 of the chapter entitled Quality and Reliability Assurance/Handling Precautions. 030619_S
(c) 2006 TOSHIBA CORPORATION All Rights Reserved
Page 2
TMP86C845UG
Difference between TMP86C845 and TMP86Cx47 series
TMP86Cx47 series TMP86C847UG ROM RAM I/O port Package(Body size) Minumum command execution time Supply Voltage 8192bytes (MASK) 512bytes 35 pins LQFP44(10x10mm) TMP86CH47UG TMP86CH47AUG 16384bytes(MASK) 512bytes 35 pins LQFP44(10x10mm) 0.25sec at 16MHz 1.8V to 5.5V at 4.2MHz/32.768kHz 2.7V to 5.5V at 8.0MHz/32.768kHz 4.5V to 5.5V at 16MHz/32.768kHz 16-bit timer counter: 1ch 8-bit timer counter: 2ch 1ch 1ch 1ch Hi-Speed SIO : 1ch 4ch Analog-input : 8ch 6 kinds 16-bit timer counter: 1ch 8-bit timer counter: 2ch 1ch 1ch 1ch Hi-Speed SIO : 1ch 4ch Analog-input : 8ch 6 kinds 16-bit timer counter: 1ch 8-bit timer counter: 2ch 1ch 1ch 1ch Hi-Speed SIO : 1ch 4ch Analog-input : 8ch 6 kinds TMP86CM47UG TMP86CM47AUG 32768bytes(MASK) 1024bytes 35 pins LQFP44(10x10mm) TMP86C845 series TMP86C845UG 8192bytes(MASK) 256bytes 35 pins LQFP44(10x10mm) 0.5sec at 16MHz 2.7V to 5.5V at 8.0MHz/32.768kHz 8-bit timer counter: 2ch 1ch 1ch Hi-Speed SIO : 1ch Analog-input : 8ch 4 kinds P2 port and ,P00,P05,P06,P07, P10,P11,P12,P15 pins P3, P4 ports and P01,P02,P03,P04, P13,P14,P16,P17 pins
RESET input only
Timer counter Time base timer Watch dog timer UART SIO Key-on wakeup 10-bit AD converter Warming-up counter for releasing STOP mode Hysterisis input pin
P0,P1,P2 ports
P0,P1,P2 ports
P0,P1,P2 ports
I/O circuit
CMOS input pin
RESET
P3,P4 ports
P3,P4 ports
P3,P4 ports
pin Operating Temperature Package (P-LQFP44-1010-0.80A) Package (P-LQFP44-1010-0.80B) -40 to 85 Available N.A.
Watch dog timer, Address trap and Systemclock reset output -40 to 85 (Note2) Available (86CH47) Available (86CH47A) -40 to 85 Available N.A.
-40 to 85 Available N.A.
Note 1: Please make sure to check the section "Pin Input/Output port" of TMP86C847/H47/M47 and TMP86C845. Note 2: With TMP86CH47AUG the operating temperature (Topr) is -20 to 85 when the supply voltage VDD is less than 2.0V.
Page 3
TMP86C845UG
Revision History
Date 2006/6/13 2006/6/29 2006/6/29 2006/8/3 Revision 1 2 3 4 First Release Periodical updating.No change in contents. Periodical updating.No change in contents. Contents Revised
Table of Contents
TMP86C845UG
1.1 1.2 1.3 1.4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pin Names and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3 4 5
2. Operational Description
2.1 CPU Core Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Memory Address Map............................................................................................................................... 7 Program Memory (MaskROM).................................................................................................................. 7 Data Memory (RAM) ................................................................................................................................. 7 Clock Generator........................................................................................................................................ 8 Timing Generator .................................................................................................................................... 10 Operation Mode Control Circuit .............................................................................................................. 11
Single-clock mode Dual-clock mode STOP mode Configuration of timing generator Machine cycle
2.2
2.1.1 2.1.2 2.1.3 2.2.1 2.2.2 2.2.3
System Clock Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2.2.1 2.2.2.2 2.2.3.1 2.2.3.2 2.2.3.3 2.2.4.1 2.2.4.2 2.2.4.3 2.2.4.4
2.2.4
Operating Mode Control ......................................................................................................................... 16
STOP mode IDLE1/2 mode and SLEEP1/2 mode IDLE0 and SLEEP0 modes (IDLE0, SLEEP0) SLOW mode
2.3
Reset Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
External Reset Input ............................................................................................................................... 29 Address trap reset .................................................................................................................................. 30 Watchdog timer reset.............................................................................................................................. 30 System clock reset.................................................................................................................................. 30
2.3.1 2.3.2 2.3.3 2.3.4
3. Interrupt Control Circuit
3.1 3.2 3.3 3.4 Interrupt latches (IL15 to IL2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Interrupt enable register (EIR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Interrupt Source Selector (INTSEL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Interrupt Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Interrupt acceptance processing is packaged as follows........................................................................ 37 Saving/restoring general-purpose registers ............................................................................................ 38
Using PUSH and POP instructions
3.2.1 3.2.2
Interrupt master enable flag (IMF) .......................................................................................................... 34 Individual interrupt enable flags (EF15 to EF4) ...................................................................................... 34
3.4.1 3.4.2
3.4.2.1
i
3.5
3.4.3 3.5.1 3.5.2
3.4.2.2
Software Interrupt (INTSW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Undefined Instruction Interrupt (INTUNDEF). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Address Trap Interrupt (INTATRAP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 External Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Address error detection .......................................................................................................................... 41 Debugging .............................................................................................................................................. 41
Interrupt return ........................................................................................................................................ 40
Using data transfer instructions
3.6 3.7 3.8
4. Special Function Register (SFR)
4.1 SFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
5. I/O Ports
5.1 5.2 5.3 5.4 5.5 Port P0 (P07 to P00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P1 (P17 to P10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P2 (P22 to P20) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P3 (P37 to P30) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port P4 (P47 to P40) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 49 50 51 52
6. Time Base Timer (TBT)
6.1 Time Base Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Configuration .......................................................................................................................................... 53 Control .................................................................................................................................................... 53 Function .................................................................................................................................................. 54 Configuration .......................................................................................................................................... 55 Control .................................................................................................................................................... 55 6.1.1 6.1.2 6.1.3 6.2.1 6.2.2
6.2
Divider Output (DVO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
7. Watchdog Timer (WDT)
7.1 7.2 Watchdog Timer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Watchdog Timer Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Malfunction Detection Methods Using the Watchdog Timer ................................................................... Watchdog Timer Enable ......................................................................................................................... Watchdog Timer Disable ........................................................................................................................ Watchdog Timer Interrupt (INTWDT)...................................................................................................... Watchdog Timer Reset ........................................................................................................................... Selection of Address Trap in Internal RAM (ATAS) ................................................................................ Selection of Operation at Address Trap (ATOUT) .................................................................................. Address Trap Interrupt (INTATRAP)....................................................................................................... Address Trap Reset ................................................................................................................................ 58 59 60 60 61
7.3
7.2.1 7.2.2 7.2.3 7.2.4 7.2.5
Address Trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
62 62 62 63
7.3.1 7.3.2 7.3.3 7.3.4
8. 8-Bit TimerCounter (TC3, TC4)
8.1 8.2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 TimerCounter Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
ii
8.3
Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
8-Bit Timer Mode (TC3 and 4) ................................................................................................................ 8-Bit Event Counter Mode (TC3, 4) ........................................................................................................ 8-Bit Programmable Divider Output (PDO) Mode (TC3, 4)..................................................................... 8-Bit Pulse Width Modulation (PWM) Output Mode (TC3, 4).................................................................. 16-Bit Timer Mode (TC3 and 4) .............................................................................................................. 16-Bit Event Counter Mode (TC3 and 4) ................................................................................................ 16-Bit Pulse Width Modulation (PWM) Output Mode (TC3 and 4).......................................................... 16-Bit Programmable Pulse Generate (PPG) Output Mode (TC3 and 4) ............................................... Warm-Up Counter Mode.........................................................................................................................
Low-Frequency Warm-up Counter Mode (NORMAL1 NORMAL2 SLOW2 SLOW1) High-Frequency Warm-Up Counter Mode (SLOW1 SLOW2 NORMAL2 NORMAL1)
8.3.1 8.3.2 8.3.3 8.3.4 8.3.5 8.3.6 8.3.7 8.3.8 8.3.9
71 72 72 75 77 78 78 81 83
8.3.9.1 8.3.9.2
9. Synchronous Serial Interface (SIO)
9.1 9.2 9.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Serial clock ............................................................................................................................................. 88 Transfer bit direction ............................................................................................................................... 90
Transmit mode Receive mode Transmit/receive mode Transmit mode Receive mode Transmit/receive mode Clock source Shift edge 9.3.1.1 9.3.1.2 9.3.2.1 9.3.2.2 9.3.2.3 9.3.3.1 9.3.3.2 9.3.3.3
9.3.1 9.3.2
9.3.3
Transfer modes....................................................................................................................................... 91
10. 10-bit AD Converter (ADC)
10.1 10.2 10.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Register configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Software Start Mode ........................................................................................................................... 107 Repeat Mode ...................................................................................................................................... 107 Register Setting ................................................................................................................................ 108
10.4 10.5 10.6
10.3.1 10.3.2 10.3.3
STOP/SLOW Modes during AD Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Analog Input Voltage and AD Conversion Result . . . . . . . . . . . . . . . . . . . . . . . 110 Precautions about AD Converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Analog input pin voltage range ........................................................................................................... 111 Analog input shared pins .................................................................................................................... 111 Noise Countermeasure ....................................................................................................................... 111
10.6.1 10.6.2 10.6.3
11. Input/Output Circuitry
11.1 11.2 Control Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Input/Output Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
12. Electrical Characteristics
12.1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
iii
12.2 12.3 12.4 12.5 12.6 12.7
Recommended Operating Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AD Conversion Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recommended Oscillating Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handling Precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
117 118 119 120 120 121
13. Package Dimension
This is a technical document that describes the operating functions and electrical specifications of the 8-bit microcontroller series TLCS-870/C (LSI).
iv
TMP86C845UG
CMOS 8-Bit Microcontroller
TMP86C845UG
Product No. TMP86C845UG ROM (MaskROM) 8192 bytes RAM 256 bytes Package P-LQFP44-1010-0.80A FLASH MCU TMP86FH47AUG Emulation Chip TMP86C947XB
1.1 Features
1. 8-bit single chip microcomputer TLCS-870/C series - Instruction execution time : 0.25 s (at 16 MHz) 122 s (at 32.768 kHz) - 132 types & 731 basic instructions 2. 15interrupt sources (External : 6 Internal : 9) 3. Input / Output ports (35 pins) Large current output: 19pins (Typ. 20mA), LED direct drive 4. Prescaler - Time base timer - Divider output function 5. Watchdog Timer 6. 8-bit timer counter : 2 ch - Timer, Event counter, Programmable divider output (PDO), Pulse width modulation (PWM) output, Programmable pulse generation (PPG) modes 7. High-Speed SIO: 1ch 8. 10-bit successive approximation type AD converter - Analog input: 8 ch 9. Clock operation
060116EBP
* The information contained herein is subject to change without notice. 021023_D * TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc. 021023_A * The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunctionor failure of which may cause loss of human life or bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer's own risk. 021023_B * The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. 060106_Q * The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others. 021023_C * The products described in this document are subject to the foreign exchange and foreign trade laws. 021023_E * For a discussion of how the reliability of microcontrollers can be predicted, please refer to Section 1.3 of the chapter entitled Quality and Reliability Assurance/Handling Precautions. 030619_S
Page 1
1.1 Features
TMP86C845UG
Single clock mode Dual clock mode 10. Low power consumption operation STOP mode: Oscillation stops. (Battery/Capacitor back-up.) SLOW1 mode: Low power consumption operation using low-frequency clock.(High-frequency clock stop.) SLOW2 mode: Low power consumption operation using low-frequency clock.(High-frequency clock oscillate.) IDLE0 mode: CPU stops, and only the Time-Based-Timer(TBT) on peripherals operate using high frequency clock. Release by falling edge of the source clock which is set by TBTCR. IDLE1 mode: CPU stops and peripherals operate using high frequency clock. Release by interruputs(CPU restarts). IDLE2 mode: CPU stops and peripherals operate using high and low frequency clock. Release by interruputs. (CPU restarts). SLEEP0 mode: CPU stops, and only the Time-Based-Timer(TBT) on peripherals operate using low frequency clock.Release by falling edge of the source clock which is set by TBTCR. SLEEP1 mode: CPU stops, and peripherals operate using low frequency clock. Release by interruput.(CPU restarts). SLEEP2 mode: CPU stops and peripherals operate using high and low frequency clock. interruput. 11. Wide operation voltage:
2.7 V to 5.5 V at 8MHz /32.768 kHz
Release by
Page 2
1.2 Pin Assignment
VAREF AVDD AVSS P40 P41 P42 P43 P44 P45 P46 P47
34 35 36 37 38 39 40 41 42 43 44
VSS XIN XOUT TEST VDD (XTIN) P21 (XTOUT) P22
RESET
Figure 1-1 Pin Assignment
Page 3
(STOP/INT5) P20 (INT0) P00 (PDO4/PWM4/PPG4/TC4) P01
1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 12
33 32 31 30 29 28 27 26 25 24 23
P37 (AIN7) P36 (AIN6) P35 (AIN5) P34 (AIN4) P33 (AIN3) P32 (AIN2) P31 (AIN1) P30 (AIN0) P10 (TC3/PDO3/PWM3) P11 (INT1) P12 (INT2)
P13(DVO) P14 P15(INT3) P16 P17 P07(INT4) P06(SCK) P05(SI) P04(SO) P03 P02
TMP86C845UG
1.3 Block Diagram
TMP86C845UG
1.3 Block Diagram
Figure 1-2 Block Diagram
Page 4
TMP86C845UG
1.4 Pin Names and Functions
Table 1-1 Pin Names and Functions(1/2)
Pin Name P07 INT4 P06
SCK
Pin Number 17
Input/Output IO I IO IO IO I IO O IO IO IO I O IO I IO IO IO I IO IO O IO I IO I IO I O IO O PORT07 External interrupt 4 input PORT06 Serial clock input/output PORT05 Serial data input PORT04 Serial data output PORT03 PORT02
Functions
16
P05 SI P04 SO P03 P02 P01 TC4
PDO4/PWM4/PPG4
15
14 13 12
11
PORT01 TC4 input PDO4/PWM4/PPG4 output PORT00 External interrupt 0 input PORT17 PORT16 PORT15 External interrupt 3 input PORT14 PORT13 Divider Output PORT12 External interrupt 2 input PORT11 External interrupt 1 input PORT10 TC3 input PDO3/PWM3 output PORT22 Resonator connecting pins(32.768kHz) for inputting external clock PORT21 Resonator connecting pins(32.768kHz) for inputting external clock PORT20 External interrupt 5 input STOP mode release signal input PORT37 Analog Input7 PORT36 Analog Input6 PORT35 Analog Input5
P00
INT0
10 18 19 20 21 22
P17 P16 P15 INT3 P14 P13
DVO
P12 INT2 P11 INT1 P10 TC3
PDO3/PWM3
23
24
25
P22 XTOUT
7
P21 XTIN P20
INT5 STOP
6
IO I IO I I IO I IO I IO I
9
P37 AIN7 P36 AIN6 P35 AIN5
33
32
31
Page 5
1.4 Pin Names and Functions
TMP86C845UG
Table 1-1 Pin Names and Functions(2/2)
Pin Name P34 AIN4 P33 AIN3 P32 AIN2 P31 AIN1 P30 AIN0 P47 P46 P45 P44 P43 P42 P41 P40 XIN XOUT
RESET
Pin Number 30
Input/Output IO I IO I IO I IO I IO I IO IO IO IO IO IO IO IO I O I I I I I I I PORT34 Analog Input4 PORT33 Analog Input3 PORT32 Analog Input2 PORT31 Analog Input1 PORT30 Analog Input0 PORT47 PORT46 PORT45 PORT44 PORT43 PORT42 PORT41 PORT40
Functions
29
28
27
26 44 43 42 41 40 39 38 37 2 3 8 4 34 35 36 5 1
Resonator connecting pins for high-frequency clock Resonator connecting pins for high-frequency clock Reset signal Test pin for out-going test. Normally, be fixed to low. Analog Base Voltage Input Pin for A/D Conversion Analog Power Supply Analog Power Supply +5V 0(GND)
TEST VAREF AVDD AVSS VDD VSS
Page 6
TMP86C845UG
2. Operational Description
2.1 CPU Core Functions
The CPU core consists of a CPU, a system clock controller, and an interrupt controller. This section provides a description of the CPU core, the program memory, the data memory, and the reset circuit.
2.1.1
Memory Address Map
The TMP86C845UG memory is composed MaskROM, RAM and SFR(Special function register). They are all mapped in 64-Kbyte address space. Figure 2-1 shows the TMP86C845UG memory address map.
0000H
SFR
003FH 0040H
64 bytes
SFR:
RAM
013FH E000H
256 bytes
RAM:
Special function register includes: I/O ports Peripheral control registers Peripheral status registers System control registers Program status word Random access memory includes: Data memory Stack
MaskROM:
Program memory
MaskROM
FFC0H FFDFH FFE0H FFFFH
8192 bytes
Vector table for vector call instructions (32 bytes) Vector table for interrupts (32 bytes)
Figure 2-1 Memory Address Map 2.1.2 Program Memory (MaskROM)
The TMP86C845UG has a 8192 bytes (Address E000H to FFFFH) of program memory (MaskROM ).
2.1.3
Data Memory (RAM)
The TMP86C845UG has 256bytes (Address 0040H to 013FH) of internal RAM. The first 192 bytes (0040H to 00FFH) of the internal RAM are located in the direct area; instructions with shorten operations are available against such an area. The data memory contents become unstable when the power supply is turned on; therefore, the data memory should be initialized by an initialization routine.
Page 7
2. Operational Description
2.2 System Clock Controller TMP86C845UG
Example :Clears RAM to "00H". (TMP86C845UG)
LD LD LD SRAMCLR: LD INC DEC JRS HL, 0040H A, H BC, 00FFH (HL), A HL BC F, SRAMCLR ; Start address setup ; Initial value (00H) setup
2.2 System Clock Controller
The system clock controller consists of a clock generator, a timing generator, and a standby controller.
Timing generator control register Clock generator
XIN fc TBTCR 0036H
High-frequency clock oscillator
XOUT XTIN
Timing generator
fs
Standby controller
0038H SYSCR1 0039H SYSCR2
Low-frequency clock oscillator
XTOUT
System clocks Clock generator control
System control registers
Figure 2-2 System Colck Control 2.2.1 Clock Generator
The clock generator generates the basic clock which provides the system clocks supplied to the CPU core and peripheral hardware. It contains two oscillation circuits: One for the high-frequency clock and one for the low-frequency clock. Power consumption can be reduced by switching of the standby controller to low-power operation based on the low-frequency clock. The high-frequency (fc) clock and low-frequency (fs) clock can easily be obtained by connecting a resonator between the XIN/XOUT and XTIN/XTOUT pins respectively. Clock input from an external oscillator is also possible. In this case, external clock is applied to XIN/XTIN pin with XOUT/XTOUT pin not connected.
Page 8
TMP86C845UG
High-frequency clock XIN XOUT XIN XOUT (Open) XTIN
Low-frequency clock XTOUT XTIN XTOUT (Open)
(a) Crystal/Ceramic resonator
(b) External oscillator
(c) Crystal
(d) External oscillator
Figure 2-3 Examples of Resonator Connection
Note:The function to monitor the basic clock directly at external is not provided for hardware, however, with disabling all interrupts and watchdog timers, the oscillation frequency can be adjusted by monitoring the pulse which the fixed frequency is outputted to the port by the program. The system to require the adjustment of the oscillation frequency should create the program for the adjustment in advance.
Page 9
2. Operational Description
2.2 System Clock Controller TMP86C845UG
2.2.2
Timing Generator
The timing generator generates the various system clocks supplied to the CPU core and peripheral hardware from the basic clock (fc or fs). The timing generator provides the following functions. 1. Generation of main system clock 2. Generation of divider output (DVO) pulses 3. Generation of source clocks for time base timer 4. Generation of source clocks for watchdog timer 5. Generation of internal source clocks for timer/counters 6. Generation of warm-up clocks for releasing STOP mode
2.2.2.1
Configuration of timing generator
The timing generator consists of a 2-stage prescaler, a 21-stage divider, a main system clock generator, and machine cycle counters. An input clock to the 7th stage of the divider depends on the operating mode, SYSCR2 and TBTCR, that is shown in Figure 2-4. As reset and STOP mode started/canceled, the prescaler and the divider are cleared to "0".
fc or fs
Main system clock generator
SYSCK DV7CK
Machine cycle counters
High-frequency clock fc Low-frequency clock fs
12
fc/4
S A 123456 B Y
Divider
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 S B0 B1 A0 Y0 A1 Y1
Multiplexer
Multiplexer
Warm-up controller
Watchdog timer
Timer counter, Serial interface, Time-base-timer, divider output, etc. (Peripheral functions)
Figure 2-4 Configuration of Timing Generator
Page 10
TMP86C845UG
Timing Generator Control Register
TBTCR (0036H) 7 (DVOEN) 6 (DVOCK) 5 4 DV7CK 3 (TBTEN) 2 1 (TBTCK) 0 (Initial value: 0000 0000)
DV7CK
Selection of input to the 7th stage of the divider
0: fc/28 [Hz] 1: fs
R/W
Note 1: In single clock mode, do not set DV7CK to "1". Note 2: Do not set "1" on DV7CK while the low-frequency clock is not operated stably. Note 3: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *: Don't care Note 4: In SLOW1/2 and SLEEP1/2 modes, the DV7CK setting is ineffective, and fs is input to the 7th stage of the divider. Note 5: When STOP mode is entered from NORMAL1/2 mode, the DV7CK setting is ineffective during the warm-up period after release of STOP mode, and the 6th stage of the divider is input to the 7th stage during this period.
2.2.2.2
Machine cycle
Instruction execution and peripheral hardware operation are synchronized with the main system clock. The minimum instruction execution unit is called an "machine cycle". There are a total of 10 different types of instructions for the TLCS-870/C Series: Ranging from 1-cycle instructions which require one machine cycle for execution to 10-cycle instructions which require 10 machine cycles for execution. A machine cycle consists of 4 states (S0 to S3), and each state consists of one main system clock.
1/fc or 1/fs [s]
Main system clock
State
S0
S1
S2
S3
S0
S1
S2
S3
Machine cycle
Figure 2-5 Machine Cycle 2.2.3 Operation Mode Control Circuit
The operation mode control circuit starts and stops the oscillation circuits for the high-frequency and lowfrequency clocks, and switches the main system clock. There are three operating modes: Single clock mode, dual clock mode and STOP mode. These modes are controlled by the system control registers (SYSCR1 and SYSCR2). Figure 2-6 shows the operating mode transition diagram.
2.2.3.1
Single-clock mode
Only the oscillation circuit for the high-frequency clock is used, and P21 (XTIN) and P22 (XTOUT) pins are used as input/output ports. The main-system clock is obtained from the high-frequency clock. In the single-clock mode, the machine cycle time is 4/fc [s]. (1) NORMAL1 mode In this mode, both the CPU core and on-chip peripherals operate using the high-frequency clock. The TMP86C845UG is placed in this mode after reset.
Page 11
2. Operational Description
2.2 System Clock Controller TMP86C845UG
(2)
IDLE1 mode In this mode, the internal oscillation circuit remains active. The CPU and the watchdog timer are halted; however on-chip peripherals remain active (Operate using the high-frequency clock). IDLE1 mode is started by SYSCR2 = "1", and IDLE1 mode is released to NORMAL1 mode by an interrupt request from the on-chip peripherals or external interrupt inputs. When the IMF (Interrupt master enable flag) is "1" (Interrupt enable), the execution will resume with the acceptance of the interrupt, and the operation will return to normal after the interrupt service is completed. When the IMF is "0" (Interrupt disable), the execution will resume with the instruction which follows the IDLE1 mode start instruction.
(3)
IDLE0 mode In this mode, all the circuit, except oscillator and the timer-base-timer, stops operation. This mode is enabled by SYSCR2 = "1". When IDLE0 mode starts, the CPU stops and the timing generator stops feeding the clock to the peripheral circuits other than TBT. Then, upon detecting the falling edge of the source clock selected with TBTCR, the timing generator starts feeding the clock to all peripheral circuits. When returned from IDLE0 mode, the CPU restarts operating, entering NORMAL1 mode back again. IDLE0 mode is entered and returned regardless of how TBTCR is set. When IMF = "1", EF6 (TBT interrupt individual enable flag) = "1", and TBTCR = "1", interrupt processing is performed. When IDLE0 mode is entered while TBTCR = "1", the INTTBT interrupt latch is set after returning to NORMAL1 mode.
2.2.3.2
Dual-clock mode
Both the high-frequency and low-frequency oscillation circuits are used in this mode. P21 (XTIN) and P22 (XTOUT) pins cannot be used as input/output ports. The main system clock is obtained from the high-frequency clock in NORMAL2 and IDLE2 modes, and is obtained from the low-frequency clock in SLOW and SLEEP modes. The machine cycle time is 4/fc [s] in the NORMAL2 and IDLE2 modes, and 4/fs [s] (122 s at fs = 32.768 kHz) in the SLOW and SLEEP modes. The TLCS-870/C is placed in the signal-clock mode during reset. To use the dual-clock mode, the lowfrequency oscillator should be turned on at the start of a program. (1) NORMAL2 mode In this mode, the CPU core operates with the high-frequency clock. On-chip peripherals operate using the high-frequency clock and/or low-frequency clock. (2) SLOW2 mode In this mode, the CPU core operates with the low-frequency clock, while both the high-frequency clock and the low-frequency clock are operated. As the SYSCR2 becomes "1", the hardware changes into SLOW2 mode. As the SYSCR2 becomes "0", the hardware changes into NORMAL2 mode. As the SYSCR2 becomes "0", the hardware changes into SLOW1 mode. Do not clear SYSCR2 to "0" during SLOW2 mode. (3) SLOW1 mode This mode can be used to reduce power-consumption by turning off oscillation of the high-frequency clock. The CPU core and on-chip peripherals operate using the low-frequency clock.
Page 12
TMP86C845UG
Switching back and forth between SLOW1 and SLOW2 modes are performed by SYSCR2. In SLOW1 and SLEEP modes, the input clock to the 1st stage of the divider is stopped; output from the 1st to 6th stages is also stopped. (4) IDLE2 mode In this mode, the internal oscillation circuit remain active. The CPU and the watchdog timer are halted; however, on-chip peripherals remain active (Operate using the high-frequency clock and/or the low-frequency clock). Starting and releasing of IDLE2 mode are the same as for IDLE1 mode, except that operation returns to NORMAL2 mode. (5) SLEEP1 mode In this mode, the internal oscillation circuit of the low-frequency clock remains active. The CPU, the watchdog timer, and the internal oscillation circuit of the high-frequency clock are halted; however, on-chip peripherals remain active (Operate using the low-frequency clock). Starting and releasing of SLEEP mode are the same as for IDLE1 mode, except that operation returns to SLOW1 mode. In SLOW1 and SLEEP1 modes, the input clock to the 1st stage of the divider is stopped; output from the 1st to 6th stages is also stopped. (6) SLEEP2 mode The SLEEP2 mode is the idle mode corresponding to the SLOW2 mode. The status under the SLEEP2 mode is same as that under the SLEEP1 mode, except for the oscillation circuit of the highfrequency clock. (7) SLEEP0 mode In this mode, all the circuit, except oscillator and the timer-base-timer, stops operation. This mode is enabled by setting "1" on bit SYSCR2. When SLEEP0 mode starts, the CPU stops and the timing generator stops feeding the clock to the peripheral circuits other than TBT. Then, upon detecting the falling edge of the source clock selected with TBTCR, the timing generator starts feeding the clock to all peripheral circuits. When returned from SLEEP0 mode, the CPU restarts operating, entering SLOW1 mode back again. SLEEP0 mode is entered and returned regardless of how TBTCR is set. When IMF = "1", EF6 (TBT interrupt individual enable flag) = "1", and TBTCR = "1", interrupt processing is performed. When SLEEP0 mode is entered while TBTCR = "1", the INTTBT interrupt latch is set after returning to SLOW1 mode.
2.2.3.3
STOP mode
In this mode, the internal oscillation circuit is turned off, causing all system operations to be halted. The internal status immediately prior to the halt is held with a lowest power consumption during STOP mode. STOP mode is started by the system control register 1 (SYSCR1), and STOP mode is released by a inputting (Either level-sensitive or edge-sensitive can be programmably selected) to the STOP pin. After the warm-up period is completed, the execution resumes with the instruction which follows the STOP mode start instruction.
Page 13
2. Operational Description
2.2 System Clock Controller TMP86C845UG
IDLE0 mode
Reset release
RESET
IDLE1 mode (a) Single-clock mode
Note 2 SYSCR2 = "1" SYSCR1 = "1" SYSCR2 = "1" NORMAL1 mode Interrupt STOP pin input SYSCR2 = "0" SYSCR2 = "1" SYSCR2 = "1" SYSCR1 = "1" STOP pin input SYSCR2 = "1" STOP SYSCR2 = "1" SLOW2 mode Interrupt SYSCR2 = "1" SYSCR2 = "0" SLOW1 mode SYSCR1 = "1" STOP pin input SYSCR2 = "1" SLEEP0 mode
IDLE2 mode
Interrupt
NORMAL2 mode
SYSCR2 = "0" SLEEP2 mode
SLEEP1 mode (b) Dual-clock mode
SYSCR2 = "1" Interrupt Note 2
Note 1: NORMAL1 and NORMAL2 modes are generically called NORMAL; SLOW1 and SLOW2 are called SLOW; IDLE0, IDLE1 and IDLE2 are called IDLE; SLEEP0, SLEEP1 and SLEEP2 are called SLEEP. Note 2: The mode is released by falling edge of TBTCR setting.
Figure 2-6 Operating Mode Transition Diagram
Table 2-1 Operating Mode and Conditions
Oscillator Operating Mode High Frequency Low Frequency CPU Core TBT Other Peripherals Reset Operate 4/fc [s] Machine Cycle Time
RESET NORMAL1 Single clock IDLE1 IDLE0 STOP NORMAL2 IDLE2 SLOW2 Dual clock SLEEP2 SLOW1 SLEEP1 SLEEP0 STOP Stop Stop Oscillation Stop Oscillation
Reset Operate Stop Halt
Reset
Operate
Halt Operate with high frequency
Halt
-
4/fc [s]
Oscillation
Halt Operate with low frequency Halt Operate with low frequency Operate
Operate
4/fs [s]
Halt Halt
Halt
-
Page 14
TMP86C845UG
System Control Register 1
SYSCR1 (0038H) 7 STOP 6 RELM 5 RETM 4 OUTEN 3 WUT 2 1 0 (Initial value: 0000 00**)
STOP RELM RETM OUTEN
STOP mode start Release method for STOP mode Operating mode after STOP mode Port output during STOP mode
0: CPU core and peripherals remain active 1: CPU core and peripherals are halted (Start STOP mode) 0: Edge-sensitive release 1: Level-sensitive release 0: Return to NORMAL1/2 mode 1: Return to SLOW1 mode 0: High impedance 1: Output kept Return to NORMAL mode Return to SLOW mode 3 x 213/fs 213/fs 3 x 26/fs 26/fs
R/W R/W R/W R/W
WUT
Warm-up time at releasing STOP mode
00 01 10 11
3 x 216/fc 216/fc 3 x 214/fc 214/fc
R/W
Note 1: Always set RETM to "0" when transiting from NORMAL mode to STOP mode. Always set RETM to "1" when transiting from SLOW mode to STOP mode. Note 2: When STOP mode is released with RESET pin input, a return is made to NORMAL1 regardless of the RETM contents. Note 3: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *; Don't care Note 4: Bits 1 and 0 in SYSCR1 are read as undefined data when a read instruction is executed. Note 5: As the hardware becomes STOP mode under OUTEN = "0", input value is fixed to "0"; therefore it may cause external interrupt request on account of falling edge. Note 6: Port P20 is used as STOP pin. Therefore, when stop mode is started, OUTEN does not affect to P20, and P20 becomes High-Z mode. Note 7: The warmig-up time should be set correctly for using oscillator.
System Control Register 2
SYSCR2 (0039H) 7 XEN 6 XTEN 5 SYSCK 4 IDLE 3 2
TGHALT
1
0 (Initial value: 1000 *0**)
XEN XTEN
High-frequency oscillator control Low-frequency oscillator control Main system clock select (Write)/main system clock monitor (Read) CPU and watchdog timer control (IDLE1/2 and SLEEP1/2 modes) TG control (IDLE0 and SLEEP0 modes)
0: Turn off oscillation 1: Turn on oscillation 0: Turn off oscillation 1: Turn on oscillation 0: High-frequency clock (NORMAL1/NORMAL2/IDLE1/IDLE2) 1: Low-frequency clock (SLOW1/SLOW2/SLEEP1/SLEEP2) 0: CPU and watchdog timer remain active 1: CPU and watchdog timer are stopped (Start IDLE1/2 and SLEEP1/2 modes) 0: Feeding clock to all peripherals from TG 1: Stop feeding clock to peripherals except TBT from TG. (Start IDLE0 and SLEEP0 modes) R/W R/W
SYSCK
IDLE
TGHALT
Note 1: A reset is applied if both XEN and XTEN are cleared to "0", XEN is cleared to "0" when SYSCK = "0", or XTEN is cleared to "0" when SYSCK = "1". Note 2: *: Don't care, TG: Timing generator, *; Don't care Note 3: Bits 3, 1 and 0 in SYSCR2 are always read as undefined value. Note 4: Do not set IDLE and TGHALT to "1" simultaneously. Note 5: Because returning from IDLE0/SLEEP0 to NORMAL1/SLOW1 is executed by the asynchronous internal clock, the period of IDLE0/SLEEP0 mode might be shorter than the period setting by TBTCR. Note 6: When IDLE1/2 or SLEEP1/2 mode is released, IDLE is automatically cleared to "0". Note 7: When IDLE0 or SLEEP0 mode is released, TGHALT is automatically cleared to "0". Note 8: Before setting TGHALT to "1", be sure to stop peripherals. If peripherals are not stopped, the interrupt latch of peripherals may be set after IDLE0 or SLEEP0 mode is released.
Page 15
2. Operational Description
2.2 System Clock Controller TMP86C845UG
2.2.4
Operating Mode Control
STOP mode
STOP mode is controlled by the system control register 1, the STOP pin input. The STOP pin is also used both as a port P20 and an INT5 (external interrupt input 5) pin. STOP mode is started by setting SYSCR1 to "1". During STOP mode, the following status is maintained. 1. Oscillations are turned off, and all internal operations are halted. 2. The data memory, registers, the program status word and port output latches are all held in the status in effect before STOP mode was entered. 3. The prescaler and the divider of the timing generator are cleared to "0". 4. The program counter holds the address 2 ahead of the instruction (e.g., [SET (SYSCR1).7]) which started STOP mode. STOP mode includes a level-sensitive mode and an edge-sensitive mode, either of which can be selected with the SYSCR1.
2.2.4.1
Note 1: During STOP period (from start of STOP mode to end of warm up), due to changes in the external interrupt pin signal, interrupt latches may be set to "1" and interrupts may be accepted immediately after STOP mode is released. Before starting STOP mode, therefore, disable interrupts. Also, before enabling interrupts after STOP mode is released, clear unnecessary interrupt latches.
(1)
Level-sensitive release mode (RELM = "1") In this mode, STOP mode is released by setting the STOP pin high. This mode is used for capacitor backup when the main power supply is cut off and long term battery backup. Even if an instruction for starting STOP mode is executed while STOP pin input is high, STOP mode does not start but instead the warm-up sequence starts immediately. Thus, to start STOP mode in the level-sensitive release mode, it is necessary for the program to first confirm that the STOP pin input is low. The following two methods can be used for confirmation. 1. Testing a port. 2. Using an external interrupt input INT5 (INT5 is a falling edge-sensitive input).
Example 1 :Starting STOP mode from NORMAL mode by testing a port P20.
LD SSTOPH: TEST JRS DI SET (SYSCR1). 7 (SYSCR1), 01010000B (P2PRD). 0 F, SSTOPH ; IMF 0 ; Starts STOP mode ; Sets up the level-sensitive release mode ; Wait until the STOP pin input goes low level
Example 2 :Starting STOP mode from NORMAL mode with an INT5 interrupt.
PINT5: TEST JRS LD DI SET SINT5: RETI (SYSCR1). 7 (P2PRD). 0 F, SINT5 (SYSCR1), 01010000B ; To reject noise, STOP mode does not start if port P20 is at high ; Sets up the level-sensitive release mode. ; IMF 0 ; Starts STOP mode
Page 16
TMP86C845UG
STOP pin XOUT pin NORMAL operation STOP operation Confirm by program that the STOP pin input is low and start STOP mode.
VIH
Warm up
NORMAL operation
STOP mode is released by the hardware. Always released if the STOP pin input is high.
Figure 2-7 Level-sensitive Release Mode
Note 1: Even if the STOP pin input is low after warm-up start, the STOP mode is not restarted. Note 2: In this case of changing to the level-sensitive mode from the edge-sensitive mode, the release mode is not switched until a rising edge of the STOP pin input is detected.
(2)
Edge-sensitive release mode (RELM = "0") In this mode, STOP mode is released by a rising edge of the STOP pin input. This is used in applications where a relatively short program is executed repeatedly at periodic intervals. This periodic signal (for example, a clock from a low-power consumption oscillator) is input to the STOP pin. In the edge-sensitive release mode, STOP mode is started even when the STOP pin input is high level.
Example :Starting STOP mode from NORMAL mode
DI LD (SYSCR1), 10010000B ; IMF 0 ; Starts after specified to the edge-sensitive release mode
STOP pin XOUT pin
NORMAL operation STOP mode started by the program. STOP operation
VIH
Warm up NORMAL operation
STOP operation
STOP mode is released by the hardware at the rising edge of STOP pin input.
Figure 2-8 Edge-sensitive Release Mode
STOP mode is released by the following sequence. 1. In the dual-clock mode, when returning to NORMAL2, both the high-frequency and lowfrequency clock oscillators are turned on; when returning to SLOW1 mode, only the lowfrequency clock oscillator is turned on. In the single-clock mode, only the high-frequency clock oscillator is turned on. 2. A warm-up period is inserted to allow oscillation time to stabilize. During warm up, all internal operations remain halted. Four different warm-up times can be selected with the SYSCR1 in accordance with the resonator characteristics.
Page 17
2. Operational Description
2.2 System Clock Controller TMP86C845UG
3. When the warm-up time has elapsed, normal operation resumes with the instruction following the STOP mode start instruction.
Note 1: When the STOP mode is released, the start is made after the prescaler and the divider of the timing generator are cleared to "0". Note 2: STOP mode can also be released by inputting low level on the RESET pin, which immediately performs the normal reset operation. Note 3: When STOP mode is released with a low hold voltage, the following cautions must be observed. The power supply voltage must be at the operating voltage level before releasing STOP mode. The RESET pin input must also be "H" level, rising together with the power supply voltage. In this case, if an external time constant circuit has been connected, the RESET pin input voltage will increase at a slower pace than the power supply voltage. At this time, there is a danger that a reset may occur if input voltage level of the RESET pin drops below the non-inverting high-level input voltage (Hysteresis input).
Table 2-2 Warm-up Time Example (at fc = 16.0 MHz, fs = 32.768 kHz)
Warm-up Time [ms] WUT Return to NORMAL Mode 00 01 10 11 12.288 4.096 3.072 1.024 Return to SLOW Mode 750 250 5.85 1.95
Note 1: The warm-up time is obtained by dividing the basic clock by the divider. Therefore, the warm-up time may include a certain amount of error if there is any fluctuation of the oscillation frequency when STOP mode is released. Thus, the warm-up time must be considered as an approximate value.
Page 18
Turn off
Oscillator circuit
Turn on
Main system clock a+3 SET (SYSCR1). 7 n+1 (a) STOP mode start (Example: Start with SET (SYSCR1). 7 instruction located at address a) n+2 n+3 n+4 Halt
Program counter
a+2
Instruction execution
Divider
n
0
Figure 2-9 STOP Mode Start/Release
a+4
Instruction address a + 2
Page 19
0 1 (b) STOP mode release
Warm up
STOP pin input
Oscillator circuit
Turn off
Turn on
Main system clock a+5
Instruction address a + 3
Program counter
a+3
a+6
Instruction address a + 4
Instruction execution
Halt
Divider
0
Count up
2
3
TMP86C845UG
2. Operational Description
2.2 System Clock Controller TMP86C845UG
2.2.4.2
IDLE1/2 mode and SLEEP1/2 mode
IDLE1/2 and SLEEP1/2 modes are controlled by the system control register 2 (SYSCR2) and maskable interrupts. The following status is maintained during these modes. 1. Operation of the CPU and watchdog timer (WDT) is halted. On-chip peripherals continue to operate. 2. The data memory, CPU registers, program status word and port output latches are all held in the status in effect before these modes were entered. 3. The program counter holds the address 2 ahead of the instruction which starts these modes.
Starting IDLE1/2 and SLEEP1/2 modes by instruction
CPU and WDT are halted
Yes Reset input No No Interrupt request Yes "0" IMF
Reset
Normal release mode
"1" (Interrupt release mode) Interrupt processing
Execution of the instruction which follows the IDLE1/2 and SLEEP1/2 modes start instruction
Figure 2-10 IDLE1/2 and SLEEP1/2 Modes
Page 20
TMP86C845UG
* Start the IDLE1/2 and SLEEP1/2 modes After IMF is set to "0", set the individual interrupt enable flag (EF) which releases IDLE1/2 and SLEEP1/2 modes. To start IDLE1/2 and SLEEP1/2 modes, set SYSCR2 to "1". * Release the IDLE1/2 and SLEEP1/2 modes IDLE1/2 and SLEEP1/2 modes include a normal release mode and an interrupt release mode. These modes are selected by interrupt master enable flag (IMF). After releasing IDLE1/2 and SLEEP1/2 modes, the SYSCR2 is automatically cleared to "0" and the operation mode is returned to the mode preceding IDLE1/2 and SLEEP1/2 modes. IDLE1/2 and SLEEP1/2 modes can also be released by inputting low level on the RESET pin. After releasing reset, the operation mode is started from NORMAL1 mode. (1) Normal release mode (IMF = "0") IDLE1/2 and SLEEP1/2 modes are released by any interrupt source enabled by the individual interrupt enable flag (EF). After the interrupt is generated, the program operation is resumed from the instruction following the IDLE1/2 and SLEEP1/2 modes start instruction. Normally, the interrupt latches (IL) of the interrupt source used for releasing must be cleared to "0" by load instructions. (2) Interrupt release mode (IMF = "1") IDLE1/2 and SLEEP1/2 modes are released by any interrupt source enabled with the individual interrupt enable flag (EF) and the interrupt processing is started. After the interrupt is processed, the program operation is resumed from the instruction following the instruction, which starts IDLE1/2 and SLEEP1/2 modes.
Note: When a watchdog timer interrupts is generated immediately before IDLE1/2 and SLEEP1/2 modes are started, the watchdog timer interrupt will be processed but IDLE1/2 and SLEEP1/2 modes will not be started.
Page 21
Main system clock
2.2 System Clock Controller
2. Operational Description
Interrupt request a+2 SET (SYSCR2). 4 Operate Halt a+3
Program counter
Instruction execution
Watchdog timer
(a) IDLE1/2 and SLEEP1/2 modes start (Example: Starting with the SET instruction located at address a)
Main system clock
Interrupt request a+3 Instruction address a + 2 Operate Normal release mode a+4
Program counter
Figure 2-11 IDLE1/2 and SLEEP1/2 Modes Start/Release
Page 22
a+3 Acceptance of interrupt Operate Operate Interrupt release mode
Instruction execution
Halt
Watchdog timer
Halt
Main system clock
Interrupt request
Program counter
Instruction execution
Halt
Watchdog timer
Halt
TMP86C845UG
(b) IDLE1/2 and SLEEP1/2 modes release
TMP86C845UG
2.2.4.3
IDLE0 and SLEEP0 modes (IDLE0, SLEEP0)
IDLE0 and SLEEP0 modes are controlled by the system control register 2 (SYSCR2) and the time base timer control register (TBTCR). The following status is maintained during IDLE0 and SLEEP0 modes. 1. Timing generator stops feeding clock to peripherals except TBT. 2. The data memory, CPU registers, program status word and port output latches are all held in the status in effect before IDLE0 and SLEEP0 modes were entered. 3. The program counter holds the address 2 ahead of the instruction which starts IDLE0 and SLEEP0 modes.
Note: Before starting IDLE0 or SLEEP0 mode, be sure to stop (Disable) peripherals.
Stopping peripherals by instruction
Starting IDLE0, SLEEP0 modes by instruction
CPU and WDT are halted
Reset input No No TBT source clock falling edge Yes TBTCR = "1" Yes TBT interrupt enable Yes No IMF = "1"
Yes
Reset
No
No
(Normal release mode)
Yes (Interrupt release mode) Interrupt processing
Execution of the instruction which follows the IDLE0, SLEEP0 modes start instruction
Figure 2-12 IDLE0 and SLEEP0 Modes
Page 23
2. Operational Description
2.2 System Clock Controller TMP86C845UG
* Start the IDLE0 and SLEEP0 modes Stop (Disable) peripherals such as a timer counter. To start IDLE0 and SLEEP0 modes, set SYSCR2 to "1". * Release the IDLE0 and SLEEP0 modes IDLE0 and SLEEP0 modes include a normal release mode and an interrupt release mode. These modes are selected by interrupt master flag (IMF), the individual interrupt enable flag of TBT and TBTCR. After releasing IDLE0 and SLEEP0 modes, the SYSCR2 is automatically cleared to "0" and the operation mode is returned to the mode preceding IDLE0 and SLEEP0 modes. Before starting the IDLE0 or SLEEP0 mode, when the TBTCR is set to "1", INTTBT interrupt latch is set to "1". IDLE0 and SLEEP0 modes can also be released by inputting low level on the RESET pin. After releasing reset, the operation mode is started from NORMAL1 mode.
Note: IDLE0 and SLEEP0 modes start/release without reference to TBTCR setting.
(1)
Normal release mode (IMF*EF6*TBTCR = "0") IDLE0 and SLEEP0 modes are released by the source clock falling edge, which is setting by the TBTCR. After the falling edge is detected, the program operation is resumed from the instruction following the IDLE0 and SLEEP0 modes start instruction. Before starting the IDLE0 or SLEEP0 mode, when the TBTCR is set to "1", INTTBT interrupt latch is set to "1".
(2)
Interrupt release mode (IMF*EF6*TBTCR = "1") IDLE0 and SLEEP0 modes are released by the source clock falling edge, which is setting by the TBTCR and INTTBT interrupt processing is started.
Note 1: Because returning from IDLE0, SLEEP0 to NORMAL1, SLOW1 is executed by the asynchronous internal clock, the period of IDLE0, SLEEP0 mode might be the shorter than the period setting by TBTCR. Note 2: When a watchdog timer interrupt is generated immediately before IDLE0/SLEEP0 mode is started, the watchdog timer interrupt will be processed but IDLE0/SLEEP0 mode will not be started.
Page 24
Main system clock
Interrupt request a+2 a+3
Program counter
Instruction execution
SET (SYSCR2). 2
Halt
Watchdog timer
Operate
(a) IDLE0 and SLEEP0 modes start (Example: Starting with the SET instruction located at address a
Main system clock
TBT clock a+3 a+4
Program counter
Figure 2-13 IDLE0 and SLEEP0 Modes Start/Release
Page 25
Instruction address a + 2 Operate
Normal release mode a+3
Instruction execution
Halt
Watchdog timer
Halt
Main system clock
TBT clock
Program counter
Instruction execution
Halt
Acceptance of interrupt Operate
Interrupt release mode
(b) IDLE and SLEEP0 modes release
TMP86C845UG
Watchdog timer
Halt
2. Operational Description
2.2 System Clock Controller TMP86C845UG
2.2.4.4
SLOW mode
SLOW mode is controlled by the system control register 2 (SYSCR2). The following is the methods to switch the mode with the warm-up counter. (1) Switching from NORMAL2 mode to SLOW1 mode First, set SYSCR2 to switch the main system clock to the low-frequency clock for SLOW2 mode. Next, clear SYSCR2 to turn off high-frequency oscillation.
Note: The high-frequency clock can be continued oscillation in order to return to NORMAL2 mode from SLOW mode quickly. Always turn off oscillation of high-frequency clock when switching from SLOW mode to stop mode.
Example 1 :Switching from NORMAL2 mode to SLOW1 mode.
SET (SYSCR2). 5 ; SYSCR2 1 (Switches the main system clock to the low-frequency clock for SLOW2) CLR (SYSCR2). 7 ; SYSCR2 0 (Turns off high-frequency oscillation)
Example 2 :Switching to the SLOW1 mode after low-frequency clock has stabilized.
SET LD LD LDW DI SET EI SET : PINTTC4: CLR SET (TC4CR). 3 (SYSCR2). 5 ; Stops TC4, 3 ; SYSCR2 1 (Switches the main system clock to the low-frequency clock) CLR (SYSCR2). 7 ; SYSCR2 0 (Turns off high-frequency oscillation) RETI : VINTTC4: DW PINTTC4 ; INTTC4 vector table (TC4CR). 3 (EIRH). 1 (SYSCR2). 6 (TC3CR), 43H (TC4CR), 05H (TTREG3), 8000H ; SYSCR2 1 ; Sets mode for TC4, 3 (16-bit mode, fs for source) ; Sets warming-up counter mode ; Sets warm-up time (Depend on oscillator accompanied) ; IMF 0 ; Enables INTTC4 ; IMF 1 ; Starts TC4, 3
Page 26
TMP86C845UG
(2)
Switching from SLOW1 mode to NORMAL2 mode First, set SYSCR2 to turn on the high-frequency oscillation. When time for stabilization (Warm up) has been taken by the timer/counter (TC4,TC3), clear SYSCR2 to switch the main system clock to the high-frequency clock. SLOW mode can also be released by inputting low level on the RESET pin. After releasing reset, the operation mode is started from NORMAL1 mode.
Note: After SYSCK is cleared to "0", executing the instructions is continiued by the low-frequency clock for the period synchronized with low-frequency and high-frequency clocks.
High-frequency clock Low-frequency clock Main system clock SYSCK
Example :Switching from the SLOW1 mode to the NORMAL2 mode (fc = 16 MHz, warm-up time is 4.0 ms).
SET LD LD LD DI SET EI SET : PINTTC4: CLR CLR (TC4CR). 3 (SYSCR2). 5 ; Stops TC4, 3 ; SYSCR2 0 (Switches the main system clock to the high-frequency clock) RETI : VINTTC4: DW PINTTC4 ; INTTC4 vector table (TC4CR). 3 (EIRH). 1 (SYSCR2). 7 (TC3CR), 63H (TC4CR), 05H (TTREG4), 0F8H ; SYSCR2 1 (Starts high-frequency oscillation) ; Sets mode for TC4, 3 (16-bit mode, fc for source) ; Sets warming-up counter mode ; Sets warm-up time ; IMF 0 ; Enables INTTC4 ; IMF 1 ; Starts TC4, 3
Page 27
2.2 System Clock Controller
2. Operational Description
Highfrequency clock Lowfrequency clock Main system clock Turn off
SYSCK
XEN CLR (SYSCR2). 7 SLOW2 mode (a) Switching to the SLOW mode
Instruction execution
SET (SYSCR2). 5
NORMAL2 mode
SLOW1 mode
Figure 2-14 Switching between the NORMAL2 and SLOW Modes
Page 28
CLR (SYSCR2). 5 Warm up during SLOW2 mode (b) Switching to the NORMAL2 mode
Highfrequency clock Lowfrequency clock Main system clock
SYSCK
XEN
Instruction execution
SET (SYSCR2). 7
TMP86C845UG
SLOW1 mode
NORMAL2 mode
TMP86C845UG
2.3 Reset Circuit
The TMP86C845UG has four types of reset generation procedures: An external reset input, an address trap reset, a watchdog timer reset and a system clock reset. Of these reset, the address trap reset, the watchdog timer and the system clock reset are a malfunction reset. When the malfunction reset request is detected, reset occurs during the maximum 24/fc[s]. The malfunction reset circuit such as watchdog timer reset, address trap reset and system clock reset is not initialized when power is turned on. Therefore, reset may occur during maximum 24/fc[s] (1.5s at 16.0 MHz) when power is turned on. Table 2-3 shows on-chip hardware initialization by reset action. Table 2-3 Initializing Internal Status by Reset Action
On-chip Hardware Program counter Stack pointer General-purpose registers (W, A, B, C, D, E, H, L, IX, IY) Jump status flag Zero flag Carry flag Half carry flag Sign flag Overflow flag Interrupt master enable flag Interrupt individual enable flags Interrupt latches (JF) (ZF) (CF) (HF) (SF) (VF) (IMF) (EF) (IL) (PC) (SP) Initial Value (FFFEH) Not initialized Not initialized Not initialized Not initialized Not initialized Not initialized Output latches of I/O ports Not initialized Not initialized 0 0 Control registers 0 RAM Refer to each of control register Not initialized Refer to I/O port circuitry Watchdog timer Enable Prescaler and divider of timing generator 0 On-chip Hardware Initial Value
2.3.1
External Reset Input
The RESET pin contains a Schmitt trigger (Hysteresis) with an internal pull-up resistor. When the RESET pin is held at "L" level for at least 3 machine cycles (12/fc [s]) with the power supply voltage within the operating voltage range and oscillation stable, a reset is applied and the internal state is initialized. When the RESET pin input goes high, the reset operation is released and the program execution starts at the vector address stored at addresses FFFEH to FFFFH.
VDD
RESET
Internal reset Watchdog timer reset Malfunction reset output circuit Address trap reset System clock reset
Figure 2-15 Reset Circuit
Page 29
2. Operational Description
2.3 Reset Circuit TMP86C845UG
2.3.2
Address trap reset
If the CPU should start looping for some cause such as noise and an attempt be made to fetch an instruction from the on-chip RAM (when WDTCR1 is set to "1") or the SFR area, address trap reset will be generated. The reset time is maximum 24/fc[s] (1.5s at 16.0 MHz).
Note:The operating mode under address trapped is alternative of reset or interrupt. The address trap area is alternative.
Instruction execution Internal reset
JP a Address trap is occurred
Reset release
Instruction at address r
maximum 24/fc [s]
4/fc to 12/fc [s]
16/fc [s]
Note 1: Address "a" is in the SFR or on-chip RAM (WDTCR1 = "1") space. Note 2: During reset release, reset vector "r" is read out, and an instruction at address "r" is fetched and decoded.
Figure 2-16 Address Trap Reset 2.3.3 Watchdog timer reset
Refer to Section "Watchdog Timer".
2.3.4
System clock reset
If the condition as follows is detected, the system clock reset occurs automatically to prevent dead lock of the CPU. (The oscillation is continued without stopping.) - In case of clearing SYSCR2 and SYSCR2 simultaneously to "0". - In case of clearing SYSCR2 to "0", when the SYSCR2 is "0". - In case of clearing SYSCR2 to "0", when the SYSCR2 is "1". The reset time is maximum 24/fc (1.5 s at 16.0 MHz).
Page 30
TMP86C845UG
Page 31
2. Operational Description
2.3 Reset Circuit TMP86C845UG
Page 32
TMP86C845UG
3. Interrupt Control Circuit
The TMP86C845UG has a total of 15 interrupt sources excluding reset, of which 2 source levels are multiplexed. Interrupts can be nested with priorities. Four of the internal interrupt sources are non-maskable while the rest are maskable. Interrupt sources are provided with interrupt latches (IL), which hold interrupt requests, and independent vectors. The interrupt latch is set to "1" by the generation of its interrupt request which requests the CPU to accept its interrupts. Interrupts are enabled or disabled by software using the interrupt master enable flag (IMF) and interrupt enable flag (EF). If more than one interrupts are generated simultaneously, interrupts are accepted in order which is dominated by hardware. However, there are no prioritized interrupt factors among non-maskable interrupts.
Interrupt Latch - - - IL2 IL3 IL4 IL5 IL6 IL7 IL8 IL9 IL10 IL11 IL12 IL13 IL14 Vector Address FFFE FFFC FFFC FFFA FFF8 FFF6 FFF4 FFF2 FFF0 FFEE FFEC FFEA FFE8 FFE6 FFE4 FFE2
Interrupt Factors Internal/External Internal Internal Internal Internal External External Internal External Internal Internal External Internal External External Internal (Reset) INTSWI (Software interrupt) INTUNDEF (Executed the undefined instruction interrupt) INTATRAP (Address trap interrupt) INTWDT (Watchdog timer interrupt)
INT0
Enable Condition Non-maskable Non-maskable Non-maskable Non-maskable Non-maskable IMF* EF4 = 1, INT0EN = 1 IMF* EF5 = 1 IMF* EF6 = 1 IMF* EF7 = 1 IMF* EF8 = 1 IMF* EF9 = 1 IMF* EF10 = 1 IMF* EF11 = 1 IMF* EF12 = 1 IMF* EF13 = 1 IMF* EF14 = 1, IL14ER = 0 IMF* EF14 = 1, IL14ER = 1 IMF* EF15 = 1, IL15ER = 0 IMF* EF15 = 1, IL15ER = 1
Priority 1 2 2 2 2 5 6 7 8 9 10 11 12 13 14 15
INT1 INTTBT Reserved INT2 INTTC4 INTTC3 INT3 INTSIO Reserved INT4 (Don't set)
INT5
IL15
FFE0
16
INTADC
Note 1: The INTSEL register is used to select the interrupt source to be enabled for each multiplexed source level (see 3.3 Interrupt Source Selector (INTSEL)). Note 2: To use the address trap interrupt (INTATRAP), clear WDTCR1 to "0" (It is set for the "reset request" after reset is cancelled). For details, see "Address Trap". Note 3: To use the watchdog timer interrupt (INTWDT), clear WDTCR1 to "0" (It is set for the "Reset request" after reset is released). For details, see "Watchdog Timer".
3.1 Interrupt latches (IL15 to IL2)
An interrupt latch is provided for each interrupt source, except for a software interrupt and an executed the undefined instruction interrupt. When interrupt request is generated, the latch is set to "1", and the CPU is requested to accept the interrupt if its interrupt is enabled. The interrupt latch is cleared to "0" immediately after accepting interrupt. All interrupt latches are initialized to "0" during reset. The interrupt latches are located on address 003CH and 003DH in SFR area. Each latch can be cleared to "0" individually by instruction. However, IL2 and IL3 should not be cleared to "0" by software. For clearing the interrupt latch, load instruction should be used and then IL2 and IL3 should be set to "1". If the read-modify-write instructions such as bit manipulation or operation instructions are used, interrupt request would be cleared inadequately if interrupt is requested while such instructions are executed. Interrupt latches are not set to "1" by an instruction. Page 33
3. Interrupt Control Circuit
3.2 Interrupt enable register (EIR) TMP86C845UG
Since interrupt latches can be read, the status for interrupt requests can be monitored by software.
Note: In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1".
Example 1 :Clears interrupt latches
DI LDW EI (ILL), 1110100000111111B ; IMF 0 ; IL12, IL10 to IL6 0 ; IMF 1
Example 2 :Reads interrupt latchess
LD WA, (ILL) ; W ILH, A ILL
Example 3 :Tests interrupt latches
TEST JR (ILL). 7 F, SSET ; if IL7 = 1 then jump
3.2 Interrupt enable register (EIR)
The interrupt enable register (EIR) enables and disables the acceptance of interrupts, except for the non-maskable interrupts (Software interrupt, undefined instruction interrupt, address trap interrupt and watchdog interrupt). Nonmaskable interrupt is accepted regardless of the contents of the EIR. The EIR consists of an interrupt master enable flag (IMF) and the individual interrupt enable flags (EF). These registers are located on address 003AH and 003BH in SFR area, and they can be read and written by an instructions (Including read-modify-write instructions such as bit manipulation or operation instructions).
3.2.1
Interrupt master enable flag (IMF)
The interrupt enable register (IMF) enables and disables the acceptance of the whole maskable interrupt. While IMF = "0", all maskable interrupts are not accepted regardless of the status on each individual interrupt enable flag (EF). By setting IMF to "1", the interrupt becomes acceptable if the individuals are enabled. When an interrupt is accepted, IMF is cleared to "0" after the latest status on IMF is stacked. Thus the maskable interrupts which follow are disabled. By executing return interrupt instruction [RETI/RETN], the stacked data, which was the status before interrupt acceptance, is loaded on IMF again. The IMF is located on bit0 in EIRL (Address: 003AH in SFR), and can be read and written by an instruction. The IMF is normally set and cleared by [EI] and [DI] instruction respectively. During reset, the IMF is initialized to "0".
3.2.2
Individual interrupt enable flags (EF15 to EF4)
Each of these flags enables and disables the acceptance of its maskable interrupt. Setting the corresponding bit of an individual interrupt enable flag to "1" enables acceptance of its interrupt, and setting the bit to "0" disables acceptance. During reset, all the individual interrupt enable flags (EF15 to EF4) are initialized to "0" and all maskable interrupts are not accepted until they are set to "1".
Note:In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1".
Page 34
TMP86C845UG
Example 1 :Enables interrupts individually and sets IMF
DI LDW : : EI ; IMF 1 (EIRL), 1110100010100000B ; IMF 0 ; EF15 to EF13, EF11, EF7, EF5 1 Note: IMF should not be set.
Example 2 :C compiler description example
unsigned int _io (3AH) EIRL; _DI(); EIRL = 10100000B; : _EI(); /* 3AH shows EIRL address */
Page 35
3. Interrupt Control Circuit
3.2 Interrupt enable register (EIR) TMP86C845UG
Interrupt Latches
(Initial value: 00000000 000000**) ILH,ILL (003DH, 003CH) 15 IL15 14 IL14 13 IL13 12 IL12 11 IL11 10 IL10 9 IL9 8 IL8 7 IL7 6 IL6 5 IL5 4 IL4 3 IL3 2 IL2 1 0
ILH (003DH)
ILL (003CH)
IL15 to IL2
Interrupt latches
at RD 0: No interrupt request 1: Interrupt request
at WR 0: Clears the interrupt request 1: (Interrupt latch is not set.)
R/W
Note 1: To clear any one of bits IL7 to IL4, be sure to write "1" into IL2 and IL3. Note 2: In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1". Note 3: Do not clear IL with read-modify-write instructions such as bit operations.
Interrupt Enable Registers
(Initial value: 00000000 0000***0) EIRH,EIRL (003BH, 003AH) 15 EF15 14 EF14 13 EF13 12 EF12 11 EF11 10 EF10 9 EF9 8 EF8 7 EF7 6 EF6 5 EF5 4 EF4 EIRL (003AH) 3 2 1 0 IMF
EIRH (003BH)
EF15 to EF4 IMF
Individual-interrupt enable flag (Specified for each bit) Interrupt master enable flag
0: 1: 0: 1:
Disables the acceptance of each maskable interrupt. Enables the acceptance of each maskable interrupt. Disables the acceptance of all maskable interrupts Enables the acceptance of all maskable interrupts
R/W
Note 1: *: Don't care Note 2: Do not set IMF and the interrupt enable flag (EF15 to EF4) to "1" at the same time. Note 3: In main program, before manipulating the interrupt enable flag (EF) or the interrupt latch (IL), be sure to clear IMF to "0" (Disable interrupt by DI instruction). Then set IMF newly again as required after operating on the EF or IL (Enable interrupt by EI instruction) In interrupt service routine, because the IMF becomes "0" automatically, clearing IMF need not execute normally on interrupt service routine. However, if using multiple interrupt on interrupt service routine, manipulating EF or IL should be executed before setting IMF="1".
Page 36
TMP86C845UG
3.3 Interrupt Source Selector (INTSEL)
Each interrupt source that shares the interrupt source level with another interrupt source is allowed to enable the interrupt latch only when it is selected in the INTSEL register. The interrupt controller does not hold interrupt requests corresponding to interrupt sources that are not selected in the INTSEL register. Therefore, the INTSEL register must be set appropriately before interrupt requests are generated. The following interrupt sources share their interrupt source level; the source is selected onnthe register INTSEL. 1. INT4 and (Don't set) share the interrupt source level whose priority is 15. 2. INT5 and INTADC share the interrupt source level whose priority is 16. Interrupt source selector
INTSEL (003EH) 7 6 5 4 3 2 1 IL14ER 0 IL15ER (Initial value: **** **00)
IL14ER IL15ER
Selects INT4 or (Don't set) Selects INT5 or INTADC
0: INT4 1: (Don't set) 0: INT5 1: INTADC
R/W R/W
3.4 Interrupt Sequence
An interrupt request, which raised interrupt latch, is held, until interrupt is accepted or interrupt latch is cleared to "0" by resetting or an instruction. Interrupt acceptance sequence requires 8 machine cycles (2 s @16 MHz) after the completion of the current instruction. The interrupt service task terminates upon execution of an interrupt return instruction [RETI] (for maskable interrupts) or [RETN] (for non-maskable interrupts). Figure 3-1 shows the timing chart of interrupt acceptance processing.
3.4.1
Interrupt acceptance processing is packaged as follows.
a. The interrupt master enable flag (IMF) is cleared to "0" in order to disable the acceptance of any following interrupt. b. The interrupt latch (IL) for the interrupt source accepted is cleared to "0". c. The contents of the program counter (PC) and the program status word, including the interrupt master enable flag (IMF), are saved (Pushed) on the stack in sequence of PSW + IMF, PCH, PCL. Meanwhile, the stack pointer (SP) is decremented by 3. d. The entry address (Interrupt vector) of the corresponding interrupt service program, loaded on the vector table, is transferred to the program counter. e. The instruction stored at the entry address of the interrupt service program is executed.
Note:When the contents of PSW are saved on the stack, the contents of IMF are also saved.
Page 37
3. Interrupt Control Circuit
3.4 Interrupt Sequence TMP86C845UG
1-machine cycle
Interrupt service task
Interrupt request Interrupt latch (IL)
IMF Execute instruction a-1 Execute instruction Execute instruction
Interrupt acceptance
Execute RETI instruction
PC
a
a+1
a
b
b+1 b+2 b + 3
c+1
c+2
a
a+1 a+2
SP
n
n-1 n-2
n-3
n-2 n-1
n
Note 1: a: Return address entry address, b: Entry address, c: Address which RETI instruction is stored Note 2: On condition that interrupt is enabled, it takes 38/fc [s] or 38/fs [s] at maximum (If the interrupt latch is set at the first machine cycle on 10 cycle instruction) to start interrupt acceptance processing since its interrupt latch is set.
Figure 3-1 Timing Chart of Interrupt Acceptance/Return Interrupt Instruction
Example: Correspondence between vector table address for INTTBT and the entry address of the interrupt service program
Vector table address
Entry address Interrupt service program
FFF2H FFF3H
03H D2H
Vector
D203H D204H
0FH 06H
Figure 3-2 Vector table address,Entry address
A maskable interrupt is not accepted until the IMF is set to "1" even if the maskable interrupt higher than the level of current servicing interrupt is requested. In order to utilize nested interrupt service, the IMF is set to "1" in the interrupt service program. In this case, acceptable interrupt sources are selectively enabled by the individual interrupt enable flags. To avoid overloaded nesting, clear the individual interrupt enable flag whose interrupt is currently serviced, before setting IMF to "1". As for non-maskable interrupt, keep interrupt service shorten compared with length between interrupt requests; otherwise the status cannot be recovered as non-maskable interrupt would simply nested.
3.4.2
Saving/restoring general-purpose registers
During interrupt acceptance processing, the program counter (PC) and the program status word (PSW, includes IMF) are automatically saved on the stack, but the accumulator and others are not. These registers are saved by software if necessary. When multiple interrupt services are nested, it is also necessary to avoid using the same data memory area for saving registers. The following methods are used to save/restore the generalpurpose registers.
Page 38
TMP86C845UG
3.4.2.1
Using PUSH and POP instructions
If only a specific register is saved or interrupts of the same source are nested, general-purpose registers can be saved/restored using the PUSH/POP instructions.
Example :Save/store register using PUSH and POP instructions
PINTxx: PUSH WA ; Save WA register (interrupt processing) POP RETI WA ; Restore WA register ; RETURN
Address (Example) SP A SP PCL PCH PSW At acceptance of an interrupt W PCL PCH PSW At execution of PUSH instruction SP PCL PCH PSW At execution of POP instruction SP b-5 b-4 b-3 b-2 b-1 b At execution of RETI instruction
Figure 3-3 Save/store register using PUSH and POP instructions
3.4.2.2 Using data transfer instructions
To save only a specific register without nested interrupts, data transfer instructions are available.
Example :Save/store register using data transfer instructions
PINTxx: LD (GSAVA), A ; Save A register (interrupt processing) LD RETI A, (GSAVA) ; Restore A register ; RETURN
Page 39
3. Interrupt Control Circuit
3.4 Interrupt Sequence TMP86C845UG
Main task Interrupt acceptance Interrupt service task Saving registers
Restoring registers Interrupt return Saving/Restoring general-purpose registers using PUSH/POP data transfer instruction
Figure 3-4 Saving/Restoring General-purpose Registers under Interrupt Processing 3.4.3 Interrupt return
Interrupt return instructions [RETI]/[RETN] perform as follows.
[RETI]/[RETN] Interrupt Return 1. Program counter (PC) and program status word (PSW, includes IMF) are restored from the stack. 2. Stack pointer (SP) is incremented by 3.
As for address trap interrupt (INTATRAP), it is required to alter stacked data for program counter (PC) to restarting address, during interrupt service program.
Note:If [RETN] is executed with the above data unaltered, the program returns to the address trap area and INTATRAP occurs again.When interrupt acceptance processing has completed, stacked data for PCL and PCH are located on address (SP + 1) and (SP + 2) respectively.
Example 1 :Returning from address trap interrupt (INTATRAP) service program
PINTxx: POP LD PUSH WA WA, Return Address WA ; Recover SP by 2 ; ; Alter stacked data
(interrupt processing) RETN ; RETURN
Example 2 :Restarting without returning interrupt (In this case, PSW (Includes IMF) before interrupt acceptance is discarded.)
PINTxx: INC INC INC SP SP SP ; Recover SP by 3 ; ;
(interrupt processing) LD JP EIRL, data Restart Address ; Set IMF to "1" or clear it to "0" ; Jump into restarting address
Interrupt requests are sampled during the final cycle of the instruction being executed. Thus, the next interrupt can be accepted immediately after the interrupt return instruction is executed.
Page 40
TMP86C845UG
Note 1: It is recommended that stack pointer be return to rate before INTATRAP (Increment 3 times), if return interrupt instruction [RETN] is not utilized during interrupt service program under INTATRAP (such as Example 2). Note 2: When the interrupt processing time is longer than the interrupt request generation time, the interrupt service task is performed but not the main task.
3.5 Software Interrupt (INTSW)
Executing the SWI instruction generates a software interrupt and immediately starts interrupt processing (INTSW is highest prioritized interrupt). Use the SWI instruction only for detection of the address error or for debugging.
3.5.1
Address error detection
FFH is read if for some cause such as noise the CPU attempts to fetch an instruction from a non-existent memory address during single chip mode. Code FFH is the SWI instruction, so a software interrupt is generated and an address error is detected. The address error detection range can be further expanded by writing FFH to unused areas of the program memory. Address trap reset is generated in case that an instruction is fetched from RAM or SFR areas.
3.5.2
Debugging
Debugging efficiency can be increased by placing the SWI instruction at the software break point setting address.
3.6 Undefined Instruction Interrupt (INTUNDEF)
Taking code which is not defined as authorized instruction for instruction causes INTUNDEF. INTUNDEF is generated when the CPU fetches such a code and tries to execute it. INTUNDEF is accepted even if non-maskable interrupt is in process. Contemporary process is broken and INTUNDEF interrupt process starts, soon after it is requested.
Note: The undefined instruction interrupt (INTUNDEF) forces CPU to jump into vector address, as software interrupt (SWI) does.
3.7 Address Trap Interrupt (INTATRAP)
Fetching instruction from unauthorized area for instructions (Address trapped area) causes reset output or address trap interrupt (INTATRAP). INTATRAP is accepted even if non-maskable interrupt is in process. Contemporary process is broken and INTATRAP interrupt process starts, soon after it is requested.
Note: The operating mode under address trapped, whether to be reset output or interrupt processing, is selected on watchdog timer control register (WDTCR).
3.8 External Interrupts
The TMP86C845UG has 6 external interrupt inputs. These inputs are equipped with digital noise reject circuits (Pulse inputs of less than a certain time are eliminated as noise). Edge selection is also possible with INT1 to INT4. The INT0/P00 pin can be configured as either an external interrupt input pin or an input/output port, and is configured as an input port during reset. Edge selection, noise reject control and INT0/P00 pin function selection are performed by the external interrupt control register (EINTCR).
Page 41
3. Interrupt Control Circuit
3.8 External Interrupts TMP86C845UG
Source
Pin
Enable Conditions
Release Edge (level)
Digital Noise Reject Pulses of less than 2/fc [s] are eliminated as noise. Pulses of 7/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. Pulses of less than 15/fc or 63/fc [s] are eliminated as noise. Pulses of 49/fc or 193/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. Pulses of less than 7/fc [s] are eliminated as noise. Pulses of 25/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. Pulses of less than 7/fc [s] are eliminated as noise. Pulses of 25/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. Pulses of less than 7/fc [s] are eliminated as noise. Pulses of 25/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals. Pulses of less than 2/fc [s] are eliminated as noise. Pulses of 7/fc [s] or more are considered to be signals. In the SLOW or the SLEEP mode, pulses of less than 1/fs [s] are eliminated as noise. Pulses of 3.5/fs [s] or more are considered to be signals.
INT0
INT0
IMF
EF4
INT0EN=1
Falling edge
INT1
INT1
IMF
EF5 = 1
Falling edge or Rising edge
INT2
INT2
IMF
EF8 = 1
Falling edge or Rising edge
INT3
INT3
IMF
EF11 = 1
Falling edge or Rising edge
INT4
INT4
IMF EF14 = 1 and IL14ER=0
Falling edge, Rising edge, Falling and Rising edge or H level
INT5
INT5
IMF EF15 = 1 and IL15ER=0
Falling edge
Note 1: In NORMAL1/2 or IDLE1/2 mode, if a signal with no noise is input on an external interrupt pin, it takes a maximum of "signal establishment time + 6/fs[s]" from the input signal's edge to set the interrupt latch. Note 2: When INT0EN = "0", IL4 is not set even if a falling edge is detected on the INT0 pin input. Note 3: When a pin with more than one function is used as an output and a change occurs in data or input/output status, an interrupt request signal is generated in a pseudo manner. In this case, it is necessary to perform appropriate processing such as disabling the interrupt enable flag.
Page 42
TMP86C845UG
External Interrupt Control Register
EINTCR (0037H) 7 INT1NC 6 INT0EN 5 INT4ES 4 3 INT3ES 2 INT2ES 1 INT1ES 0 (Initial value: 0000 000*)
INT1NC INT0EN
Noise reject time select P00/INT0 pin configuration
0: Pulses of less than 63/fc [s] are eliminated as noise 1: Pulses of less than 15/fc [s] are eliminated as noise 0: P00 input/output port 1: INT0 pin (Port P00 should be set to an input mode) 00: Rising edge 01: Falling edge 10: Rising edge and Falling edge 11: H level 0: Rising edge 1: Falling edge 0: Rising edge 1: Falling edge 0: Rising edge 1: Falling edge
R/W R/W
INT4 ES
INT4 edge select
R/W
INT3 ES INT2 ES INT1 ES
INT3 edge select INT2 edge select INT1 edge select
R/W R/W R/W
Note 1: fc: High-frequency clock [Hz], *: Don't care Note 2: When the system clock frequency is switched between high and low or when the external interrupt control register (EINTCR) is overwritten, the noise canceller may not operate normally. It is recommended that external interrupts are disabled using the interrupt enable register (EIR). Note 3: The maximum time from modifying INT1NC until a noise reject time is changed is 26/fc. Note 4: In case RESET pin is released while the state of INT4 pin keeps "H" level, the external interrupt 4 request is not generated even if the INT4 edge select is specified as "H" level. The rising edge is needed after RESET pin is released.
Page 43
3. Interrupt Control Circuit
3.8 External Interrupts TMP86C845UG
Page 44
TMP86C845UG
4. Special Function Register (SFR)
The TMP86C845UG adopts the memory mapped I/O system, and all peripheral control and data transfers are performed through the special function register (SFR). The SFR is mapped on address 0000H to 003FH. This chapter shows the arrangement of the special function register (SFR) for TMP86C845UG.
4.1 SFR
Address 0000H 0001H 0002H 0003H 0004H 0005H 0006H 0007H 0008H 0009H 000AH 000BH 000CH 000DH 000EH 000FH 0010H 0011H 0012H 0013H 0014H 0015H 0016H 0017H 0018H 0019H 001AH 001BH 001CH 001DH 001EH 001FH 0020H 0021H 0022H 0023H 0024H 0025H 0026H 0027H ADCDR2 ADCDR1 Reserved Reserved Reserved Reserved Reserved Reserved SIOCR1 SIOSR P2PRD Reserved Reserved P1CR P3CR P4CR Reserved Reserved Reserved Reserved Reserved Reserved TC3CR TC4CR TTREG3 TTREG4 PWREG3 PWREG4 ADCCR1 ADCCR2 P0PRD Reserved Read P0DR P1DR P2DR P3DR P4DR Reserved Reserved Reserved Write
Page 45
4. Special Function Register (SFR)
4.1 SFR TMP86C845UG
Address 0028H 0029H 002AH 002BH 002CH 002DH 002EH 002FH 0030H 0031H 0032H 0033H 0034H 0035H 0036H 0037H 0038H 0039H 003AH 003BH 003CH 003DH 003EH 003FH
Read SIORDB Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved TBTCR EINTCR SYSCR1 SYSCR2 EIRL EIRH ILL ILH INTSEL PSW
Write SIOTDB
WDTCR1 WDTCR2
Note 1: Do not access reserved areas by the program. Note 2: - ; Cannot be accessed. Note 3: Write-only registers and interrupt latches cannot use the read-modify-write instructions (Bit manipulation instructions such as SET, CLR, etc. and logical operation instructions such as AND, OR, etc.).
Page 46
TMP86C845UG
5. I/O Ports
The TMP86C845UG has 5 parallel input/output ports (35 pins) as follows.
Primary Function Port P0 Port P1 Port P2 Port P3 Port P4 8-bit I/O port 8-bit I/O port 3-bit I/O port 8-bit I/O port 8-bit I/O port Secondary Functions External interrupt input, serial and timer/counter input/output External interrupt input, timer/counter input/output, and divider output External interrupt input, and STOP mode release signal input Analog input
Each output port contains a latch, which holds the output data. All input ports do not have latches, so the external input data should be externally held until the input data is read from outside or reading should be performed several times before processing. Figure 5-1 shows input/output timing examples. External data is read from an I/O port in the S1 state of the read cycle during execution of the read instruction. This timing cannot be recognized from outside, so that transient input such as chattering must be processed by the program. Output data changes in the S2 state of the write cycle during execution of the instruction which writes to an I/O port.
Fetch cycle Fetch cycle Read cycle
S0 S1 S2 S3 S0 S1 S2 S3 S0 S1 S2 S3 Instruction execution cycle Ex: LD A, (x)
Input strobe
Data input (a) Input timing Fetch cycle Fetch cycle Write cycle
S0 S1 S2 S3 S0 S1 S2 S3 S0 S1 S2 S3 Instruction execution cycle Ex: LD (x), A
Output strobe
Data output
Old (b) Output timing
New
Note: The positions of the read and write cycles may vary, depending on the instruction.
Figure 5-1 Input/Output Timing (Example)
Page 47
5. I/O Ports
5.1 Port P0 (P07 to P00) TMP86C845UG
5.1 Port P0 (P07 to P00)
Port P0 is an 8-bit input/output port which is also used as an external interrupt input, serial interface input/output and timer/counter input/output. When used as an input port or a secondary function pins, the respective output latch (P0DR) should be set to "1". When used as an output port, the respective P0DR bit should be set data. During reset, the output latch is initialized to "1". P0 port output latch (P0DR) and P0 port terminal input (P0PRD) are located on their respective address. When read the output latch data, the P0DR should be read and when read the terminal input data, the P0PRD register should be read. P00 port (INT0) can be configured as either an I/O port or as external interrupt input with INT0EN (bit 6 in EINTCR). During reset, P00 port (INT0) is configured as an input port.
Control input Port data (P0PRD) STOP OUTEN Output latch data (P0DR) Data output Control output a) P04 to P01 Control input Port data (P0PRD) STOP OUTEN Output latch data (P0DR) Data output Control output b) P07 to P05, P00 D Q D Q
Output latch
P0i Note: i = 4 to 1
Output latch
P0j Note: j = 7 to 5, 0
Figure 5-2 Port 0
7 P0DR (0000H) R/W
6
5
4
3
2
1 P01
PWM4
0
P07 INT4
P06
SCK
P05 SI
P04 SO
P03
P02
TC4
PDO4 PPG4
P00
INT0
(Initial value: 1111 1111)
P0PRD (0008H) Read only
7 P07
6 P06
5 P05
4 P04
3 P03
2 P02
1 P01
0 P00
Page 48
TMP86C845UG
5.2 Port P1 (P17 to P10)
Port P1 is an 8-bit input/output port which can be configured as an input or an output in one-bit unit under software control. Input/output mode is specified by the corresponding bit in the port P1 input/output control register (P1CR). Port P1 is configured as an input if its corresponding P1CR bit is cleared to "0", and as an output if its corresponding P1CR bit is set to "1". During reset, the P1CR is initialized to "0" and port P1 is input mode. The P1 output latches are also initialized to "0". Port P1 is also used as an external interrupt input, a timer/counter input/output, and a divider output. When used as an input port, an external interrupt input or a timer/counter input, the corresponding bit of P1CR is cleared to "0". When used as an output port, a timer/counter output or divider output, the corresponding bit of P1CR is set to "1" and beforehand the corresponding output latch should be set to "1". Data can be written into the output latch regardless of P1CR contents, therefore initial output data should be written into the output latch before setting P1CR.
Control input STOP OUTEN P1CRi input P1CRi D Q
Output latch Data input Data output Control output a) P17 to 16, P14 to 13 Control input STOP OUTEN P1CRj input P1CRj D Q D Q P1i Note: i = 7 to 6, 4 to 3
Output latch
Output latch Data input Data output Control output b) P15, P12 to 10 D Q P1j Note: j = 5, 2 to 0
Output latch
Figure 5-3 Port P1
7 P1DR (0001H) R/W
6
5 P15 INT3 5
4 P14
PPG
3 P13
DVO
2 P12 INT2 2
1 P11 INT1 1
0 P10
PWM3
P17
P16
TC3
PDO3
(Initial value: 0000 0000)
P1CR (000DH)
7
6
4
3
0 (Initial value: 0000 0000)
P1CR
I/O port for P1 port (specified for each bit)
0: Input mode 1: Output mode
R/W
Note: Ports set to the input mode read the pin states. Ports set to the output mode read the output latch. When input pin and output pin exist in port P1 together, the contents of the output latch which is specified as an input mode may be rewritten by executing the bit manipulation instructions.
Page 49
5. I/O Ports
5.3 Port P2 (P22 to P20) TMP86C845UG
5.3 Port P2 (P22 to P20)
Port P2 is a 3-bit input/output port. It is also used as an external interrupt, a STOP mode release signal input, and low-frequency crystal oscillator connection pins. When used as an input port or a secondary function pins, respective output latch (P2DR) should be set to "1". During reset, the P2DR is initialized to "1". A low-frequency crystal oscillator (32.768 kHz) is connected to pins P21 (XTIN) and P22 (XTOUT) in the dualclock mode. In the single-clock mode, pins P21 and P22 can be used as normal input/output ports. It is recommended that pin P20 should be used as an external interrupt input, a STOP mode release signal input, or an input port. If it is used as an output port, the interrupt latch is set on the falling edge of the output pulse. P2 port output latch (P2DR) and P2 port terminal input (P2PRD) are located on their respective address. When read the output latch data, the P2DR should be read and when read the terminal input data, the P2PRD register should be read. If a read instruction is executed for port P2, read data of bits 7 to 3 are unstable.
Data input (P20PRD) Data input (P20) Data output D Q P20 (INT5, STOP)
Output latch Control input Data input (P21PRD) Osc. enable Data input (P21) Data output Data input (P22PRD) Data input (P22) Data output D Q P22 (XTOUT) D Q P21 (XTIN)
Output latch
Output latch STOP OUTEN XTEN fs
Figure 5-4 Port 2
P2DR (0002H) R/W P2PRD (000AH) Read only
7
6
5
4
3
2 P22 XTOUT
1 P21 XTIN 1 P21
0 P20
INT5 STOP
(Initial value: **** *111)
7
6
5
4
3
2 P22
0 P20
Page 50
TMP86C845UG
5.4 Port P3 (P37 to P30)
Port P3 is an 8-bit input/output port which can be configured as an input or an output in one-bit unit under software control. Port P3 is also used as an analog input. Input/output mode is specified by the corresponding bit in the port P3 input/output control register (P3CR), and AINDS (bit 4 in ADCCR1). During reset, P3CR are initialized to "0" and AINDS is set to "1", therefore port P3 is configured as an input. When used as an analog input, set an analog input channel to SAIN (bit 0, 1, 2 in ADCCR1) and clear AINDS to "0". When AINDS is "0", the pin which is specified as an analog input is used as analog input independent on the value of P3CR and P3DR. When used as an input port, the corresponding bit of P3CR is cleared to "0" without specifying as an analog input. When the AD converter is enabled (AINDS is "0"), the data of port which is selected as an analog input is read "0". and the data of port which is not selected as an analog input is read "0" or "1", depend on the voltage level. When used as an output port, the corresponding bit of P3CR is set to "1" without specifying as an analog input. Data can be written into the output latch regardless of P3CR contents, therefore initial output data should be written into the output latch before setting P3CR. The pins not used as analog input can be used as an input/output port. But output instructions should not be executed to keep a precision. In addition, a variable signal should not be input to an adjacent port to the analog input during AD conversion.
Analog input STOP OUTEN AINDS SAIN P3CRi P3CRi input Data input (P3DR) D Q
Output latch
Data output (P3DR)
D
Q
Output latch
P3i Note: i = 7 to 0
Figure 5-5 Port 3
P3DR (0003H) R/W P3CR (000EH)
7 P37 AIN7 7
6 P36 AIN6 6
5 P35 AIN5 5
4 P34 AIN4 4
3 P33 AIN3 3
2 P32 AIN2 2
1 P31 AIN1 1
0 P30 AIN0 0 (Initial value: 0000 0000) (Initial value: 0000 0000)
P3CR
I/O control (Specified for each bit)
0: Input mode 1: Output mode
R/W
Note: Ports set to the input mode read the pin states. Ports set to the output mode read the output latch. When input pin and output pin exist in port P3 together, the contents of the output latch which is specified as an input mode may be rewritten by executing the bit manipulation instructions.
Page 51
5. I/O Ports
5.5 Port P4 (P47 to P40) TMP86C845UG
5.5 Port P4 (P47 to P40)
Port P4 is an 8-bit input/output port which can be configured as an input or an output in one-bit unit under software control. Input/output mode is specified by the corresponding bit in the port P4 input/output control register (P4CR). Port P4 is configured as an input if its corresponding P4CR bit is cleared to "0", and as an output if its corresponding P4CR bit is set to "1". During reset, the P4CR is initialized to "0" and port P4 is input mode. The P4 output latches are also initialized to "0". When used as an input port, the corresponding bit of P4CR is cleared to "0". When used as an output port, the corresponding bit of P4CR is set to "1". Data can be written into the output latch regardless of P4CR contents, therefore initial output data should be written into the output latch before setting P4CR.
STOP OUTEN P4CRi P4CRi input Data input (P4DR) D Q
Data output
D
Q
Output latch
P4i Note: i = 7 to 0
Figure 5-6 Port P4
P4DR (0004H) R/W P4CR (000FH)
7 P47 7
6 P46 6
5 P45 5
4 P44 4
3 P43 3
2 P42 2
1 P41 1
0 P40 0 (Initial value: 0000 0000) (Initial value: 0000 0000)
P4CR
I/O control for port P4 (Specified for each bit)
0: Input mode 1: Output mode
R/W
Note: Ports set to the input mode read the pin states. Ports set to the output mode read the output latch. When input pin and output pin exist in port P4 together, the contents of the output latch which is specified as an input mode may be rewritten by executing the bit manipulation instructions.
Page 52
TMP86C845UG
6. Time Base Timer (TBT)
The time base timer generates time base for key scanning, dynamic displaying, etc. It also provides a time base timer interrupt (INTTBT).
6.1 Time Base Timer
6.1.1 Configuration
MPX
fc/223 or fs/215 fc/221 or fs/213 fc/216 or fs/28 fc/214 or fs/26 fc/213 or fs/25 fc/212 or fs/24 fc/211 or fs/23 fc/29 or fs/2
Source clock
Falling edge detector
IDLE0, SLEEP0 release request
INTTBT interrupt request
3 TBTCK TBTCR Time base timer control register TBTEN
Figure 6-1 Time Base Timer configuration 6.1.2 Control
Time Base Timer is controled by Time Base Timer control register (TBTCR). Time Base Timer Control Register
7 TBTCR (0036H) (DVOEN) 6 (DVOCK) 5 4 (DV7CK) 3 TBTEN 2 1 TBTCK 0 (Initial Value: 0000 0000)
TBTEN
Time Base Timer enable / disable
0: Disable 1: Enable NORMAL1/2, IDLE1/2 Mode DV7CK = 0 000 001 fc/223 fc/221 fc/216 fc/2
14
DV7CK = 1 fs/215 fs/213 fs/28 fs/2
6
SLOW1/2 SLEEP1/2 Mode fs/215 fs/213 - - - - - - R/W
TBTCK
Time Base Timer interrupt Frequency select : [Hz]
010 011 100 101 110 111
fc/213 fc/2
12
fs/25 fs/2
4
fc/211 fc/2
9
fs/23 fs/2
Note 1: fc; High-frequency clock [Hz], fs; Low-frequency clock [Hz], *; Don't care
Page 53
6. Time Base Timer (TBT)
6.1 Time Base Timer TMP86C845UG
Note 2: The interrupt frequency (TBTCK) must be selected with the time base timer disabled (TBTEN="0"). (The interrupt frequency must not be changed with the disable from the enable state.) Both frequency selection and enabling can be performed simultaneously.
Example :Set the time base timer frequency to fc/216 [Hz] and enable an INTTBT interrupt.
LD LD DI SET (EIRL) . 6 (TBTCR) , 00000010B (TBTCR) , 00001010B ; TBTCK 010 ; TBTEN 1 ; IMF 0
Table 6-1 Time Base Timer Interrupt Frequency ( Example : fc = 16.0 MHz, fs = 32.768 kHz )
Time Base Timer Interrupt Frequency [Hz] TBTCK NORMAL1/2, IDLE1/2 Mode DV7CK = 0 000 001 010 011 100 101 110 111 1.91 7.63 244.14 976.56 1953.13 3906.25 7812.5 31250 NORMAL1/2, IDLE1/2 Mode DV7CK = 1 1 4 128 512 1024 2048 4096 16384 1 4 - - - - - - SLOW1/2, SLEEP1/2 Mode
6.1.3
Function
An INTTBT ( Time Base Timer Interrupt ) is generated on the first falling edge of source clock ( The divider output of the timing generato which is selected by TBTCK. ) after time base timer has been enabled. The divider is not cleared by the program; therefore, only the first interrupt may be generated ahead of the set interrupt period ( Figure 6-2 ).
Source clock
TBTCR
INTTBT Interrupt period Enable TBT
Figure 6-2 Time Base Timer Interrupt
Page 54
TMP86C845UG
6.2 Divider Output (DVO)
Approximately 50% duty pulse can be output using the divider output circuit, which is useful for piezoelectric buzzer drive. Divider output is from DVO pin.
6.2.1
Configuration
Output latch Data output D Q DVO pin
fc/213 or fs/25 fc/212 or fs/24 fc/211 or fs/23 fc/210 or fs/22
MPX A B CY D S 2 DVOCK TBTCR Divider output control register (a) configuration DVOEN
Port output latch TBTCR
DVO pin output (b) Timing chart
Figure 6-3 Divider Output 6.2.2 Control
The Divider Output is controlled by the Time Base Timer Control Register. Time Base Timer Control Register
7 TBTCR (0036H) DVOEN 6 DVOCK 5 4 (DV7CK) 3 (TBTEN) 2 1 (TBTCK) 0 (Initial value: 0000 0000)
DVOEN
Divider output enable / disable
0: Disable 1: Enable NORMAL1/2, IDLE1/2 Mode DV7CK = 0 DV7CK = 1 fs/25 fs/24 fs/23 fs/22 SLOW1/2 SLEEP1/2 Mode fs/25 fs/24 fs/23 fs/22
R/W
DVOCK
Divider Output (DVO) frequency selection: [Hz]
00 01 10 11
fc/213 fc/212 fc/211 fc/210
R/W
Note: Selection of divider output frequency (DVOCK) must be made while divider output is disabled (DVOEN="0"). Also, in other words, when changing the state of the divider output frequency from enabled (DVOEN="1") to disable(DVOEN="0"), do not change the setting of the divider output frequency.
Page 55
6. Time Base Timer (TBT)
6.2 Divider Output (DVO) TMP86C845UG
Example :1.95 kHz pulse output (fc = 16.0 MHz)
LD LD
(TBTCR) , 00000000B (TBTCR) , 10000000B
; DVOCK "00" ; DVOEN "1"
Table 6-2 Divider Output Frequency ( Example : fc = 16.0 MHz, fs = 32.768 kHz )
Divider Output Frequency [Hz] DVOCK NORMAL1/2, IDLE1/2 Mode DV7CK = 0 00 01 10 11 1.953 k 3.906 k 7.813 k 15.625 k DV7CK = 1 1.024 k 2.048 k 4.096 k 8.192 k SLOW1/2, SLEEP1/2 Mode 1.024 k 2.048 k 4.096 k 8.192 k
Page 56
TMP86C845UG
7. Watchdog Timer (WDT)
The watchdog timer is a fail-safe system to detect rapidly the CPU malfunctions such as endless loops due to spurious noises or the deadlock conditions, and return the CPU to a system recovery routine. The watchdog timer signal for detecting malfunctions can be programmed only once as "reset request" or "interrupt request". Upon the reset release, this signal is initialized to "reset request". When the watchdog timer is not used to detect malfunctions, it can be used as the timer to provide a periodic interrupt.
Note: Care must be taken in system design since the watchdog timer functions are not be operated completely due to effect of disturbing noise.
7.1 Watchdog Timer Configuration
Reset release
fc/2 or fs/2 fc/221 or fs/213 fc/219 or fs/211 fc/217 or fs/29
23 15
Selector
Binary counters Clock Clear 1 2 Overflow WDT output
R S Q Reset request INTWDT interrupt request
2
Interrupt request
Internal reset Q SR
WDTEN WDTT
Writing disable code
Writing clear code
WDTOUT
Controller
0034H WDTCR1
0035H WDTCR2
Watchdog timer control registers
Figure 7-1 Watchdog Timer Configuration
Page 57
7. Watchdog Timer (WDT)
7.2 Watchdog Timer Control TMP86C845UG
7.2 Watchdog Timer Control
The watchdog timer is controlled by the watchdog timer control registers (WDTCR1 and WDTCR2). The watchdog timer is automatically enabled after the reset release.
7.2.1
Malfunction Detection Methods Using the Watchdog Timer
The CPU malfunction is detected, as shown below. 1. Set the detection time, select the output, and clear the binary counter. 2. Clear the binary counter repeatedly within the specified detection time. If the CPU malfunctions such as endless loops or the deadlock conditions occur for some reason, the watchdog timer output is activated by the binary-counter overflow unless the binary counters are cleared. When WDTCR1 is set to "1" at this time, the reset request is generated and then internal hardware is initialized. When WDTCR1 is set to "0", a watchdog timer interrupt (INTWDT) is generated. The watchdog timer temporarily stops counting in the STOP mode including the warm-up or IDLE/SLEEP mode, and automatically restarts (continues counting) when the STOP/IDLE/SLEEP mode is inactivated.
Note:The watchdog timer consists of an internal divider and a two-stage binary counter. When the clear code 4EH is written, only the binary counter is cleared, but not the internal divider. The minimum binary-counter overflow time, that depends on the timing at which the clear code (4EH) is written to the WDTCR2 register, may be 3/ 4 of the time set in WDTCR1. Therefore, write the clear code using a cycle shorter than 3/4 of the time set to WDTCR1.
Example :Setting the watchdog timer detection time to 221/fc [s], and resetting the CPU malfunction detection
LD LD LD (WDTCR2), 4EH (WDTCR1), 00001101B (WDTCR2), 4EH : Clears the binary counters. : WDTT 10, WDTOUT 1 : Clears the binary counters (always clears immediately before and after changing WDTT).
Within 3/4 of WDT detection time
: :
LD
(WDTCR2), 4EH
: Clears the binary counters.
Within 3/4 of WDT detection time
: : LD (WDTCR2), 4EH : Clears the binary counters.
Page 58
TMP86C845UG
Watchdog Timer Control Register 1
WDTCR1 (0034H) 7 6 5 (ATAS) 4 (ATOUT) 3 WDTEN 2 WDTT 1 0 WDTOUT (Initial value: **11 1001)
WDTEN
Watchdog timer enable/disable
0: Disable (Writing the disable code to WDTCR2 is required.) 1: Enable NORMAL1/2 mode DV7CK = 0 DV7CK = 1 217/fs 215/fs 213/fs 211/fs SLOW1/2 mode 217/fs 215fs 213fs 211/fs
Write only
WDTT
Watchdog timer detection time [s]
00 01 10 11
225/fc 223/fc 221fc 219/fc
Write only
WDTOUT
Watchdog timer output select
0: Interrupt request 1: Reset request
Write only
Note 1: After clearing WDTOUT to "0", the program cannot set it to "1". Note 2: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *: Don't care Note 3: WDTCR1 is a write-only register and must not be used with any of read-modify-write instructions. If WDTCR1 is read, a don't care is read. Note 4: To activate the STOP mode, disable the watchdog timer or clear the counter immediately before entering the STOP mode. After clearing the counter, clear the counter again immediately after the STOP mode is inactivated. Note 5: To clear WDTEN, set the register in accordance with the procedures shown in "1.2.3 Watchdog Timer Disable".
Watchdog Timer Control Register 2
WDTCR2 (0035H) 7 6 5 4 3 2 1 0 (Initial value: **** ****)
WDTCR2
Write Watchdog timer control code
4EH: Clear the watchdog timer binary counter (Clear code) B1H: Disable the watchdog timer (Disable code) D2H: Enable assigning address trap area Others: Invalid
Write only
Note 1: The disable code is valid only when WDTCR1 = 0. Note 2: *: Don't care Note 3: The binary counter of the watchdog timer must not be cleared by the interrupt task. Note 4: Write the clear code 4EH using a cycle shorter than 3/4 of the time set in WDTCR1.
7.2.2
Watchdog Timer Enable
Setting WDTCR1 to "1" enables the watchdog timer. Since WDTCR1 is initialized to "1" during reset, the watchdog timer is enabled automatically after the reset release.
Page 59
7. Watchdog Timer (WDT)
7.2 Watchdog Timer Control TMP86C845UG
7.2.3
Watchdog Timer Disable
To disable the watchdog timer, set the register in accordance with the following procedures. Setting the register in other procedures causes a malfunction of the microcontroller. 1. Set the interrupt master flag (IMF) to "0". 2. Set WDTCR2 to the clear code (4EH). 3. Set WDTCR1 to "0". 4. Set WDTCR2 to the disable code (B1H).
Note:While the watchdog timer is disabled, the binary counters of the watchdog timer are cleared.
Example :Disabling the watchdog timer
DI LD LDW (WDTCR2), 04EH (WDTCR1), 0B101H : IMF 0 : Clears the binary coutner : WDTEN 0, WDTCR2 Disable code
Table 7-1 Watchdog Timer Detection Time (Example: fc = 16.0 MHz, fs = 32.768 kHz) Watchdog Timer Detection Time[s]
WDTT DV7CK = 0 00 01 10 11 2.097 524.288 m 131.072 m 32.768 m NORMAL1/2 mode DV7CK = 1 4 1 250 m 62.5 m SLOW mode 4 1 250 m 62.5 m
7.2.4
Watchdog Timer Interrupt (INTWDT)
When WDTCR1 is cleared to "0", a watchdog timer interrupt request (INTWDT) is generated by the binary-counter overflow. A watchdog timer interrupt is the non-maskable interrupt which can be accepted regardless of the interrupt master flag (IMF). When a watchdog timer interrupt is generated while the other interrupt including a watchdog timer interrupt is already accepted, the new watchdog timer interrupt is processed immediately and the previous interrupt is held pending. Therefore, if watchdog timer interrupts are generated continuously without execution of the RETN instruction, too many levels of nesting may cause a malfunction of the microcontroller. To generate a watchdog timer interrupt, set the stack pointer before setting WDTCR1.
Example :Setting watchdog timer interrupt
LD LD SP, 013FH (WDTCR1), 00001000B : Sets the stack pointer : WDTOUT 0
Page 60
TMP86C845UG
7.2.5
Watchdog Timer Reset
When a binary-counter overflow occurs while WDTCR1 is set to "1", a watchdog timer reset request is generated. When a watchdog timer reset request is generated, the internal hardware is reset. The reset time is maximum 24/fc [s] (1.5 s @ fc = 16.0 MHz).
Note:When a watchdog timer reset is generated in the SLOW1 mode, the reset time is maximum 24/fc (high-frequency clock) since the high-frequency clock oscillator is restarted. However, when crystals have inaccuracies upon start of the high-frequency clock oscillator, the reset time should be considered as an approximate value because it has slight errors.
219/fc [s] 217/fc Clock Binary counter Overflow INTWDT interrupt request
(WDTCR1= "0")
(WDTT=11) 1 2 3 0 1 2 3 0
Internal reset
(WDTCR1= "1")
A reset occurs Write 4EH to WDTCR2
Figure 7-2 Watchdog Timer Interrupt
Page 61
7. Watchdog Timer (WDT)
7.3 Address Trap TMP86C845UG
7.3 Address Trap
The Watchdog Timer Control Register 1 and 2 share the addresses with the control registers to generate address traps. Watchdog Timer Control Register 1
WDTCR1 (0034H) 7 6 5 ATAS 4 ATOUT 3 (WDTEN) 2 (WDTT) 1 0 (WDTOUT) (Initial value: **11 1001)
ATAS
Select address trap generation in the internal RAM area Select opertion at address trap
0: Generate no address trap 1: Generate address traps (After setting ATAS to "1", writing the control code D2H to WDTCR2 is reguired) 0: Interrupt request 1: Reset request
Write only
ATOUT
Watchdog Timer Control Register 2
WDTCR2 (0035H) 7 6 5 4 3 2 1 0 (Initial value: **** ****)
WDTCR2
Write Watchdog timer control code and address trap area control code
D2H: Enable address trap area selection (ATRAP control code) 4EH: Clear the watchdog timer binary counter (WDT clear code) B1H: Disable the watchdog timer (WDT disable code) Others: Invalid
Write only
7.3.1
Selection of Address Trap in Internal RAM (ATAS)
WDTCR1 specifies whether or not to generate address traps in the internal RAM area. To execute an instruction in the internal RAM area, clear WDTCR1 to "0". To enable the WDTCR1 setting, set WDTCR1 and then write D2H to WDTCR2. Executing an instruction in the SFR area generates an address trap unconditionally regardless of the setting in WDTCR1.
7.3.2
Selection of Operation at Address Trap (ATOUT)
When an address trap is generated, either the interrupt request or the reset request can be selected by WDTCR1.
7.3.3
Address Trap Interrupt (INTATRAP)
While WDTCR1 is "0", if the CPU should start looping for some cause such as noise and an attempt be made to fetch an instruction from the on-chip RAM (while WDTCR1 is "1") or the SFR area, address trap interrupt (INTATRAP) will be generated. An address trap interrupt is a non-maskable interrupt which can be accepted regardless of the interrupt master flag (IMF). When an address trap interrupt is generated while the other interrupt including a watchdog timer interrupt is already accepted, the new address trap is processed immediately and the previous interrupt is held pending. Therefore, if address trap interrupts are generated continuously without execution of the RETN instruction, too many levels of nesting may cause a malfunction of the microcontroller. To generate address trap interrupts, set the stack pointer beforehand.
Page 62
TMP86C845UG
7.3.4
Address Trap Reset
While WDTCR1 is "1", if the CPU should start looping for some cause such as noise and an attempt be made to fetch an instruction from the on-chip RAM (while WDTCR1 is "1") or the SFR area, address trap reset will be generated. When an address trap reset request is generated, the internal hardware is reset. The reset time is maximum 24/fc [s] (1.5 s @ fc = 16.0 MHz).
Note:When an address trap reset is generated in the SLOW1 mode, the reset time is maximum 24/fc (high-frequency clock) since the high-frequency clock oscillator is restarted. However, when crystals have inaccuracies upon start of the high-frequency clock oscillator, the reset time should be considered as an approximate value because it has slight errors.
Page 63
7. Watchdog Timer (WDT)
7.3 Address Trap TMP86C845UG
Page 64
TMP86C845UG
8. 8-Bit TimerCounter (TC3, TC4)
8.1 Configuration
PWM mode
Overflow
fc/211 or fs/23 INTTC4 interrupt request
fc/2 5 fc/2 fc/23
fs
7
fc/2 fc
TC4 pin TC4M TC4S TFF4
A B C D E F G H S
Y
A B S
Y
Clear
8-bit up-counter
TC4S
PDO, PPG mode
A 16-bit mode
16-bit mode
Y B S S A Y B
Timer, Event Counter mode
Toggle Q Set Clear
Timer F/F4
PDO4/PWM4/ PPG4 pin
TC4CK TC4CR TTREG4 PWREG4
PWM, PPG mode
DecodeEN
TFF4
PDO, PWM, PPG mode
16-bit mode
TC3S
PWM mode
fc/211 or fs/23
fc/27 5 fc/2 3 fc/2
fs
TC3 pin TC3M TC3S TFF3
fc/2 fc
A B C D E F G H S
Clear Y
8-bit up-counter Overflow 16-bit mode PDO mode
INTTC3 interrupt request
16-bit mode Timer, Event Couter mode
Toggle Q Set Clear
Timer F/F3
PDO3/PWM3/ pin
TC3CK TC3CR TTREG3 PWREG3
PWM mode
DecodeEN
TFF3
PDO, PWM mode 16-bit mode
Figure 8-1 8-Bit TimerCouter 3, 4
Page 65
8. 8-Bit TimerCounter (TC3, TC4)
8.1 Configuration TMP86C845UG
8.2 TimerCounter Control
The TimerCounter 3 is controlled by the TimerCounter 3 control register (TC3CR) and two 8-bit timer registers (TTREG3, PWREG3). TimerCounter 3 Timer Register
TTREG3 (0018H) R/W 7 6 5 4 3 2 1 0 (Initial value: 1111 1111)
PWREG3 (001AH) R/W
7
6
5
4
3
2
1
0 (Initial value: 1111 1111)
Note 1: Do not change the timer register (TTREG3) setting while the timer is running. Note 2: Do not change the timer register (PWREG3) setting in the operating mode except the 8-bit and 16-bit PWM modes while the timer is running.
TimerCounter 3 Control Register
TC3CR (0016H) 7 TFF3 6 5 TC3CK 4 3 TC3S 2 1 TC3M 0 (Initial value: 0000 0000)
TFF3
Time F/F3 control
0: 1:
Clear Set NORMAL1/2, IDLE1/2 mode DV7CK = 0 DV7CK = 1 fs/23 fc/27 fc/25 fc/23 fs fc/2 fc TC3 pin input SLOW1/2 SLEEP1/2 mode fs/23 - - - fs - fc (Note 8)
R/W
000 001 TC3CK Operating clock selection [Hz] 010 011 100 101 110 111 TC3S TC3 start control 0: 1: 000: 001: TC3M TC3M operating mode select 010: 011: 1**:
fc/211 fc/27 fc/25 fc/23 fs fc/2 fc
R/W
Operation stop and counter clear Operation start 8-bit timer/event counter mode 8-bit programmable divider output (PDO) mode 8-bit pulse width modulation (PWM) output mode 16-bit mode (Each mode is selectable with TC4M.) Reserved
R/W
R/W
Note 1: fc: High-frequency clock [Hz] fs: Low-frequency clock[Hz] Note 2: Do not change the TC3M, TC3CK and TFF3 settings while the timer is running. Note 3: To stop the timer operation (TC3S= 1 0), do not change the TC3M, TC3CK and TFF3 settings. To start the timer operation (TC3S= 0 1), TC3M, TC3CK and TFF3 can be programmed. Note 4: To use the TimerCounter in the 16-bit mode, set the operating mode by programming TC4CR, where TC3M must be fixed to 011. Note 5: To use the TimerCounter in the 16-bit mode, select the source clock by programming TC3CK. Set the timer start control and timer F/F control by programming TC4CR and TC4CR, respectively. Note 6: The operating clock settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 8-1 and Table 8-2.
Page 66
TMP86C845UG
Note 7: The timer register settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 83. Note 8: The operating clock fc in the SLOW or SLEEP mode can be used only as the high-frequency warm-up mode.
Page 67
8. 8-Bit TimerCounter (TC3, TC4)
8.1 Configuration TMP86C845UG
The TimerCounter 4 is controlled by the TimerCounter 4 control register (TC4CR) and two 8-bit timer registers (TTREG4 and PWREG4). TimerCounter 4 Timer Register
TTREG4 (0019H) R/W 7 6 5 4 3 2 1 0 (Initial value: 1111 1111)
PWREG4 (001BH) R/W
7
6
5
4
3
2
1
0 (Initial value: 1111 1111)
Note 1: Do not change the timer register (TTREG4) setting while the timer is running. Note 2: Do not change the timer register (PWREG4) setting in the operating mode except the 8-bit and 16-bit PWM modes while the timer is running.
TimerCounter 4 Control Register
TC4CR (0017H) 7 TFF4 6 5 TC4CK 4 3 TC4S 2 1 TC4M 0 (Initial value: 0000 0000)
TFF4
Timer F/F4 control
0: 1:
Clear Set NORMAL1/2, IDLE1/2 mode DV7CK = 0 DV7CK = 1 fs/23 fc/27 fc/25 fc/2 fs fc/2 fc TC4 pin input
3
R/W SLOW1/2 SLEEP1/2 mode fs/23 - - - fs - - R/W
000 001 TC4CK Operating clock selection [Hz] 010 011 100 101 110 111 TC4S TC4 start control 0: 1: 000: 001: 010: TC4M TC4M operating mode select 011: 100: 101: 110: 111:
fc/211 fc/27 fc/25 fc/2 fs fc/2 fc
3
Operation stop and counter clear Operation start 8-bit timer/event counter mode 8-bit programmable divider output (PDO) mode 8-bit pulse width modulation (PWM) output mode Reserved 16-bit timer/event counter mode Warm-up counter mode 16-bit pulse width modulation (PWM) output mode 16-bit PPG mode
R/W
R/W
Note 1: fc: High-frequency clock [Hz] fs: Low-frequency clock [Hz] Note 2: Do not change the TC4M, TC4CK and TFF4 settings while the timer is running. Note 3: To stop the timer operation (TC4S= 1 0), do not change the TC4M, TC4CK and TFF4 settings. To start the timer operation (TC4S= 0 1), TC4M, TC4CK and TFF4 can be programmed. Note 4: When TC4M= 1** (upper byte in the 16-bit mode), the source clock becomes the TC4 overflow signal regardless of the TC3CK setting. Note 5: To use the TimerCounter in the 16-bit mode, select the operating mode by programming TC4M, where TC3CR must be set to 011.
Page 68
TMP86C845UG
Note 6: To the TimerCounter in the 16-bit mode, select the source clock by programming TC3CR. Set the timer start control and timer F/F control by programming TC4S and TFF4, respectively. Note 7: The operating clock settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 8-1 and Table 8-2. Note 8: The timer register settings are limited depending on the timer operating mode. For the detailed descriptions, see Table 83.
Table 8-1 Operating Mode and Selectable Source Clock (NORMAL1/2 and IDLE1/2 Modes)
Operating mode fc/211 or fs/23 8-bit timer 8-bit event counter 8-bit PDO 8-bit PWM 16-bit timer 16-bit event counter Warm-up counter 16-bit PWM 16-bit PPG - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - fc/27 fc/25 fc/23 fs fc/2 fc TC3 pin input - - - - - TC4 pin input - - - - - - - -
Note 1: For 16-bit operations (16-bit timer/event counter, warm-up counter, 16-bit PWM and 16-bit PPG), set its source clock on lower bit (TC3CK). Note 2: : Available source clock
Table 8-2 Operating Mode and Selectable Source Clock (SLOW1/2 and SLEEP1/2 Modes)
Operating mode fc/211 or fs/23 8-bit timer 8-bit event counter 8-bit PDO 8-bit PWM 16-bit timer 16-bit event counter Warm-up counter 16-bit PWM 16-bit PPG - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - fc/27 fc/25 fc/23 fs fc/2 fc TC3 pin input - - - - - TC4 pin input - - - - - - - -
Note1: For 16-bit operations (16-bit timer/event counter, warm-up counter, 16-bit PWM and 16-bit PPG), set its source clock on lower bit (TC3CK). Note2: : Available source clock
Page 69
8. 8-Bit TimerCounter (TC3, TC4)
8.1 Configuration TMP86C845UG
Table 8-3 Constraints on Register Values Being Compared
Operating mode 8-bit timer/event counter 8-bit PDO 8-bit PWM 16-bit timer/event counter Warm-up counter 16-bit PWM 1 (TTREGn) 255 1 (TTREGn) 255 2 (PWREGn) 254 1 (TTREG4, 3) 65535 256 (TTREG4, 3) 65535 2 (PWREG4, 3) 65534 1 (PWREG4, 3) < (TTREG4, 3) 65535 16-bit PPG and (PWREG4, 3) + 1 < (TTREG4, 3) Register Value
Note: n = 3 to 4
Page 70
TMP86C845UG
8.3 Function
The TimerCounter 3 and 4 have the 8-bit timer, 8-bit event counter, 8-bit programmable divider output (PDO), 8bit pulse width modulation (PWM) output modes. The TimerCounter 3 and 4 (TC3, 4) are cascadable to form a 16bit timer. The 16-bit timer has the operating modes such as the 16-bit timer, 16-bit event counter, warm-up counter, 16-bit pulse width modulation (PWM) output and 16-bit programmable pulse generation (PPG) modes.
8.3.1
8-Bit Timer Mode (TC3 and 4)
In the timer mode, the up-counter counts up using the internal clock. When a match between the up-counter and the timer register j (TTREGj) value is detected, an INTTCj interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting.
Note 1: In the timer mode, fix TCjCR to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the timer mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the timer mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4
Table 8-4 Source Clock for TimerCounter 3, 4 (Internal Clock)
Source Clock NORMAL1/2, IDLE1/2 mode DV7CK = 0 fc/211 [Hz] fc/27 fc/25 fc/23 DV7CK = 1 fs/23 [Hz] fc/27 fc/25 fc/23 SLOW1/2, SLEEP1/2 mode fs/23 [Hz] - - - Resolution Repeated Cycle
fc = 16 MHz
fs = 32.768 kHz
fc = 16 MHz
fs = 32.768 kHz
128 s 8 s 2 s 500 ns
244.14 s - - -
32.6 ms 2.0 ms 510 s 127.5 s
62.3 ms - - -
Example :Setting the timer mode with source clock fc/27 Hz and generating an interrupt 80 s later (TimerCounter4, fc = 16.0 MHz)
LD DI SET EI LD LD (TC4CR), 00010000B (TC4CR), 00011000B : Sets the operating cock to fc/27, and 8-bit timer mode. : Starts TC4. (EIRH). 1 : Enables INTTC4 interrupt. (TTREG4), 0AH : Sets the timer register (80 s/27/fc = 0AH).
Page 71
8. 8-Bit TimerCounter (TC3, TC4)
8.1 Configuration TMP86C845UG
TC4CR
Internal Source Clock Counter
TTREG4
1
2
3
n-1
n0
1
2
n-1
n0
1
2
0
?
n
Match detect Counter clear Match detect Counter clear
INTTC4 interrupt request
Figure 8-2 8-Bit Timer Mode Timing Chart (TC4) 8.3.2 8-Bit Event Counter Mode (TC3, 4)
In the 8-bit event counter mode, the up-counter counts up at the falling edge of the input pulse to the TCj pin. When a match between the up-counter and the TTREGj value is detected, an INTTCj interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting at the falling edge of the input pulse to the TCj pin. Two machine cycles are required for the low- or high-level pulse input to the TCj pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1/2 or IDLE1/2 mode, and fs/24 Hz in the SLOW1/2 or SLEEP1/2 mode.
Note 1: In the event counter mode, fix TCjCR to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the event counter mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the event counter mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4
TC4CR TC4 pin input
Counter
TTREG4
0
1
2
n-1
n0
1
2
n-1
n0
1
2
0
?
n
Match detect Counter clear Match detect Counter clear
INTTC4 interrupt request
Figure 8-3 8-Bit Event Counter Mode Timing Chart (TC4) 8.3.3 8-Bit Programmable Divider Output (PDO) Mode (TC3, 4)
This mode is used to generate a pulse with a 50% duty cycle from the PDOj pin. In the PDO mode, the up-counter counts up using the internal clock. When a match between the up-counter and the TTREGj value is detected, the logic level output from the PDOj pin is switched to the opposite state and the up-counter is cleared. The INTTCj interrupt request is generated at the time. The logic state opposite to the timer F/Fj logic level is output from the PDOj pin. An arbitrary value can be set to the timer F/Fj by TCjCR. Upon reset, the timer F/Fj value is initialized to 0. To use the programmable divider output, set the output latch of the I/O port to 1.
Page 72
TMP86C845UG
Example :Generating 1024 Hz pulse using TC4 (fc = 16.0 MHz)
Setting port LD LD LD (TTREG4), 3DH (TC4CR), 00010001B (TC4CR), 00011001B : 1/1024/27/fc/2 = 3DH : Sets the operating clock to fc/27, and 8-bit PDO mode. : Starts TC4.
Note 1: In the programmable divider output mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the programmable divider output mode, the new value programmed in TTREGj is in effect immediately after programming. Therefore, if TTREGi is changed while the timer is running, an expected operation may not be obtained. Note 2: When the timer is stopped during PDO output, the PDOj pin holds the output status when the timer is stopped. To change the output status, program TCjCR after the timer is stopped. Do not change the TCjCR setting upon stopping of the timer. Example: Fixing the PDOj pin to the high level when the TimerCounter is stopped CLR (TCjCR).3: Stops the timer. CLR (TCjCR).7: Sets the PDOj pin to the high level. Note 3: j = 3, 4
Page 73
8.1 Configuration
8. 8-Bit TimerCounter (TC3, TC4)
TC4CR
TC4CR
Write of "1"
Internal source clock n0 1 2 n0 1 2 n0 1 2 n0 1 2 3 0
Counter
0
1
2
Figure 8-4 8-Bit PDO Mode Timing Chart (TC4)
Match detect Match detect Match detect
Page 74
TTREG4
?
n
Match detect
Timer F/F4
Set F/F
PDO4 pin
INTTC4 interrupt request
Held at the level when the timer is stopped
TMP86C845UG
TMP86C845UG
8.3.4
8-Bit Pulse Width Modulation (PWM) Output Mode (TC3, 4)
This mode is used to generate a pulse-width modulated (PWM) signals with up to 8 bits of resolution. The up-counter counts up using the internal clock. When a match between the up-counter and the PWREGj value is detected, the logic level output from the timer F/Fj is switched to the opposite state. The counter continues counting. The logic level output from the timer F/Fj is switched to the opposite state again by the up-counter overflow, and the counter is cleared. The INTTCj interrupt request is generated at this time. Since the initial value can be set to the timer F/Fj by TCjCR, positive and negative pulses can be generated. Upon reset, the timer F/Fj is cleared to 0. (The logic level output from the PWMj pin is the opposite to the timer F/Fj logic level.) Since PWREGj in the PWM mode is serially connected to the shift register, the value set to PWREGj can be changed while the timer is running. The value set to PWREGj during a run of the timer is shifted by the INTTCj interrupt request and loaded into PWREGj. While the timer is stopped, the value is shifted immediately after the programming of PWREGj. If executing the read instruction to PWREGj during PWM output, the value in the shift register is read, but not the value set in PWREGj. Therefore, after writing to PWREGj, the reading data of PWREGj is previous value until INTTCj is generated. For the pin used for PWM output, the output latch of the I/O port must be set to 1.
Note 1: In the PWM mode, program the timer register PWREGj immediately after the INTTCj interrupt request is generated (normally in the INTTCj interrupt service routine.) If the programming of PWREGj and the interrupt request occur at the same time, an unstable value is shifted, that may result in generation of the pulse different from the programmed value until the next INTTCj interrupt request is generated. Note 2: When the timer is stopped during PWM output, the PWMj pin holds the output status when the timer is stopped. To change the output status, program TCjCR after the timer is stopped. Do not change the TCjCR upon stopping of the timer. Example: Fixing the PWMj pin to the high level when the TimerCounter is stopped CLR (TCjCR).3: Stops the timer. CLR (TCjCR).7: Sets the PWMj pin to the high level. Note 3: To enter the STOP mode during PWM output, stop the timer and then enter the STOP mode. If the STOP mode is entered without stopping the timer when fc, fc/2 or fs is selected as the source clock, a pulse is output from the PWMj pin during the warm-up period time after exiting the STOP mode. Note 4: j = 3, 4
Table 8-5 PWM Output Mode
Source Clock NORMAL1/2, IDLE1/2 mode DV7CK = 0 fc/211 [Hz] fc/2 fc/2
7 5
Resolution SLOW1/2, SLEEP1/2 mode fs/23 [Hz] - - - fs - - fc = 16 MHz 128 s 8 s 2 s 500 ns 30.5 s 125 ns 62.5 ns fs = 32.768 kHz 244.14 s - - - 30.5 s - -
Repeated Cycle fc = 16 MHz 32.8 ms 2.05 ms 512 s 128 s 7.81 ms 32 s 16 s fs = 32.768 kHz 62.5 ms - - - 7.81 ms - -
DV7CK = 1 fs/23 [Hz] fc/2 fc/2
7 5
fc/23 fs fc/2 fc
fc/23 fs fc/2 fc
Page 75
8.1 Configuration
8. 8-Bit TimerCounter (TC3, TC4)
TC4CR
TC4CR
Internal source clock n
Write to PWREG4
Counter
0
1
n+1
FF
0
1
n
n+1
FF
0
1
m
m+1
FF
0
1
p
Write to PWREG4
Figure 8-5 8-Bit PWM Mode Timing Chart (TC4)
m Shift Shift m
Match detect Match detect
Page 76
n One cycle period m
PWREG4
?
n
p Shift p
Match detect
Shift
Shift registar
?
n
Match detect
Timer F/F4
PWM4 pin
n
p
INTTC4 interrupt request
TMP86C845UG
TMP86C845UG
8.3.5
16-Bit Timer Mode (TC3 and 4)
In the timer mode, the up-counter counts up using the internal clock. The TimerCounter 3 and 4 are cascadable to form a 16-bit timer. When a match between the up-counter and the timer register (TTREG3, TTREG4) value is detected after the timer is started by setting TC4CR to 1, an INTTC4 interrupt is generated and the up-counter is cleared. After being cleared, the up-counter continues counting. Program the upper byte and lower byte in this order in the timer register. (Programming only the upper or lower byte should not be attempted.)
Note 1: In the timer mode, fix TCjCR to 0. If not fixed, the PDOj, PWMj, and PPGj pins may output a pulse. Note 2: In the timer mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the timer mode, the new value programmed in TTREGj is in effect immediately after programming of TTREGj. Therefore, if TTREGj is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4
Table 8-6 Source Clock for 16-Bit Timer Mode
Source Clock NORMAL1/2, IDLE1/2 mode DV7CK = 0 fc/211 fc/27 fc/25 fc/23 DV7CK = 1 fs/23 fc/27 fc/25 fc/23 SLOW1/2, SLEEP1/2 mode fs/23 - - - Resolution fc = 16 MHz 128 s 8 s 2 s 500 ns fs = 32.768 kHz 244.14 s - - - Repeated Cycle fc = 16 MHz 8.39 s 524.3 ms 131.1 ms 32.8 ms fs = 32.768 kHz 16 s - - -
Example :Setting the timer mode with source clock fc/27 Hz, and generating an interrupt 300 ms later (fc = 16.0 MHz)
LDW DI SET EI LD (TC3CR), 13H :Sets the operating cock to fc/27, and 16-bit timer mode (lower byte). : Sets the 16-bit timer mode (upper byte). : Starts the timer. (EIRH). 1 : Enables INTTC4 interrupt. (TTREG3), 927CH : Sets the timer register (300 ms/27/fc = 927CH).
LD LD
(TC4CR), 04H (TC4CR), 0CH
TC4CR
Internal source clock Counter
TTREG3 (Lower byte) TTREG4 (Upper byte)
0
1
2
3
mn-1 mn 0
1
2
mn-1 mn 0
1
2
0
?
n
?
m
Match detect Counter clear Match detect Counter clear
INTTC4 interrupt request
Figure 8-6 16-Bit Timer Mode Timing Chart (TC3 and TC4)
Page 77
8. 8-Bit TimerCounter (TC3, TC4)
8.1 Configuration TMP86C845UG
8.3.6
16-Bit Event Counter Mode (TC3 and 4)
In the event counter mode, the up-counter counts up at the falling edge to the TC3 pin. The TimerCounter 3 and 4 are cascadable to form a 16-bit event counter. When a match between the up-counter and the timer register (TTREG3, TTREG4) value is detected after the timer is started by setting TC4CR to 1, an INTTC4 interrupt is generated and the up-counter is cleared. After being cleared, the up-counter restarts counting at the falling edge of the input pulse to the TC3 pin. Two machine cycles are required for the low- or high-level pulse input to the TC3 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1 or IDLE1 mode, and fs/24 in the SLOW1/2 or SLEEP1/2 mode. Program the lower byte (TTREG3), and upper byte (TTREG4) in this order in the timer register. (Programming only the upper or lower byte should not be attempted.)
Note 1: In the event counter mode, fix TCjCR to 0. If not fixed, the PDOj, PWMj and PPGj pins may output pulses. Note 2: In the event counter mode, do not change the TTREGj setting while the timer is running. Since TTREGj is not in the shift register configuration in the event counter mode, the new value programmed in TTREGj is in effect immediately after the programming. Therefore, if TTREGj is changed while the timer is running, an expected operation may not be obtained. Note 3: j = 3, 4
8.3.7
16-Bit Pulse Width Modulation (PWM) Output Mode (TC3 and 4)
This mode is used to generate a pulse-width modulated (PWM) signals with up to 16 bits of resolution. The TimerCounter 3 and 4 are cascadable to form the 16-bit PWM signal generator. The counter counts up using the internal clock or external clock. When a match between the up-counter and the timer register (PWREG3, PWREG4) value is detected, the logic level output from the timer F/F4 is switched to the opposite state. The counter continues counting. The logic level output from the timer F/F4 is switched to the opposite state again by the counter overflow, and the counter is cleared. The INTTC4 interrupt is generated at this time. Two machine cycles are required for the high- or low-level pulse input to the TC3 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1 or IDLE1 mode, and fs/24 to in the SLOW1/2 or SLEEP1/2 mode. Since the initial value can be set to the timer F/F4 by TC4CR, positive and negative pulses can be generated. Upon reset, the timer F/F4 is cleared to 0. (The logic level output from the PWM4 pin is the opposite to the timer F/F4 logic level.) Since PWREG4 and 3 in the PWM mode are serially connected to the shift register, the values set to PWREG4 and 3 can be changed while the timer is running. The values set to PWREG4 and 3 during a run of the timer are shifted by the INTTCj interrupt request and loaded into PWREG4 and 3. While the timer is stopped, the values are shifted immediately after the programming of PWREG4 and 3. Set the lower byte (PWREG3) and upper byte (PWREG3) in this order to program PWREG4 and 3. (Programming only the lower or upper byte of the register should not be attempted.) If executing the read instruction to PWREG4 and 3 during PWM output, the values set in the shift register is read, but not the values set in PWREG4 and 3. Therefore, after writing to the PWREG4 and 3, reading data of PWREG4 and 3 is previous value until INTTC4 is generated. For the pin used for PWM output, the output latch of the I/O port must be set to 1.
Note 1: In the PWM mode, program the timer register PWREG4 and 3 immediately after the INTTC4 interrupt request is generated (normally in the INTTC4 interrupt service routine.) If the programming of PWREGj and the interrupt request occur at the same time, an unstable value is shifted, that may result in generation of pulse different from the programmed value until the next INTTC4 interrupt request is generated. Note 2: When the timer is stopped during PWM output, the PWM4 pin holds the output status when the timer is stopped. To change the output status, program TC4CR after the timer is stopped. Do not program TC4CR upon stopping of the timer. Example: Fixing thePWM4 pin to the high level when the TimerCounter is stopped
Page 78
TMP86C845UG
CLR (TC4CR).3: Stops the timer. CLR (TC4CR).7 : Sets the PWM4 pin to the high level. Note 3: To enter the STOP mode, stop the timer and then enter the STOP mode. If the STOP mode is entered without stopping of the timer when fc, fc/2 or fs is selected as the source clock, a pulse is output from the PWM4 pin during the warm-up period time after exiting the STOP mode.
Table 8-7 16-Bit PWM Output Mode
Source Clock NORMAL1/2, IDLE1/2 mode DV7CK = 0 fc/211 fc/27 fc/25 fc/23 fs fc/2 fc DV7CK = 1 fs/23 [Hz] fc/27 fc/25 fc/23 fs fc/2 fc SLOW1/2, SLEEP1/2 mode fs/23 [Hz] - - - fs - - Resolution fc = 16 MHz 128 s 8 s 2 s 500ns 30.5 s 125 ns 62.5 ns fs = 32.768 kHz 244.14 s - - - 30.5 s - - Repeated Cycle fc = 16 MHz 8.39 s 524.3 ms 131.1 ms 32.8 ms 2 s fs = 32.768 kHz 16 s - - - 2s - -
8.2 ms 4.1 ms
Example :Generating a pulse with 1-ms high-level width and a period of 32.768 ms (fc = 16.0 MHz)
Setting ports LDW LD (PWREG3), 07D0H (TC3CR), 33H : Sets the pulse width. : Sets the operating clock to fc/23, and 16-bit PWM output mode (lower byte). : Sets TFF4 to the initial value 0, and 16-bit PWM signal generation mode (upper byte). : Starts the timer.
LD LD
(TC4CR), 056H (TC4CR), 05EH
Page 79
8.1 Configuration
8. 8-Bit TimerCounter (TC3, TC4)
TC4CR
TC4CR
Internal source clock an
Write to PWREG3
Counter
0
1
an+1
FFFF
0
1
an
an+1
FFFF
0
1
bm bm+1
Write to PWREG3
FFFF
0
1
cp
PWREG3 (Lower byte)
?
Write to PWREG4
n
m
p
Write to PWREG4
Figure 8-7 16-Bit PWM Mode Timing Chart (TC3 and TC4)
Page 80
b Shift Shift bm
Match detect an One cycle period
PWREG4 (Upper byte)
?
a
c Shift cp
Match detect Match detect
Shift
16-bit shift register
?
an
Match detect
Timer F/F4
PWM4 pin
an
bm
cp
INTTC4 interrupt request
TMP86C845UG
TMP86C845UG
8.3.8
16-Bit Programmable Pulse Generate (PPG) Output Mode (TC3 and 4)
This mode is used to generate pulses with up to 16-bits of resolution. The timer counter 3 and 4 are cascadable to enter the 16-bit PPG mode. The counter counts up using the internal clock or external clock. When a match between the up-counter and the timer register (PWREG3, PWREG4) value is detected, the logic level output from the timer F/F4 is switched to the opposite state. The counter continues counting. The logic level output from the timer F/F4 is switched to the opposite state again when a match between the up-counter and the timer register (TTREG3, TTREG4) value is detected, and the counter is cleared. The INTTC4 interrupt is generated at this time. Two machine cycles are required for the high- or low-level pulse input to the TC3 pin. Therefore, a maximum frequency to be supplied is fc/24 Hz in the NORMAL1 or IDLE1 mode, and fc/24 to in the SLOW1/2 or SLEEP1/2 mode. Since the initial value can be set to the timer F/F4 by TC4CR, positive and negative pulses can be generated. Upon reset, the timer F/F4 is cleared to 0. (The logic level output from the PPG4 pin is the opposite to the timer F/F4.) Set the lower byte and upper byte in this order to program the timer register. (TTREG3 TTREG4, PWREG3 PWREG4) (Programming only the upper or lower byte should not be attempted.) For PPG output, set the output latch of the I/O port to 1.
Example :Generating a pulse with 1-ms high-level width and a period of 16.385 ms (fc = 16.0 MHz)
Setting ports LDW LDW LD (PWREG3), 07D0H (TTREG3), 8002H (TC3CR), 33H : Sets the pulse width. : Sets the cycle period. : Sets the operating clock to fc/23, and16-bit PPG mode (lower byte). : Sets TFF4 to the initial value 0, and 16-bit PPG mode (upper byte). : Starts the timer.
LD LD
(TC4CR), 057H (TC4CR), 05FH
Note 1: In the PPG mode, do not change the PWREGi and TTREGi settings while the timer is running. Since PWREGi and TTREGi are not in the shift register configuration in the PPG mode, the new values programmed in PWREGi and TTREGi are in effect immediately after programming PWREGi and TTREGi. Therefore, if PWREGi and TTREGi are changed while the timer is running, an expected operation may not be obtained. Note 2: When the timer is stopped during PPG output, the PPG4 pin holds the output status when the timer is stopped. To change the output status, program TC4CR after the timer is stopped. Do not change TC4CR upon stopping of the timer. Example: Fixing the PPG4 pin to the high level when the TimerCounter is stopped CLR (TC4CR).3: Stops the timer CLR (TC4CR).7: Sets the PPG4 pin to the high level Note 3: i = 3, 4
Page 81
8.1 Configuration
8. 8-Bit TimerCounter (TC3, TC4)
TC4CR
TC4CR
Write of "0"
Internal source clock 1 mn mn+1 qr-1 qr 0 1 mn mn+1 1 qr-1 qr 0 mn mn+1 0
Counter
0
PWREG3 (Lower byte)
?
n
Figure 8-8 16-Bit PPG Mode Timing Chart (TC3 and TC40)
Page 82
Match detect Match detect Match detect mn mn
PWREG4 (Upper byte)
?
m
Match detect
Match detect
TTREG3 (Lower byte)
?
r
TTREG4 (Upper byte)
?
q F/F clear Held at the level when the timer stops
mn
Timer F/F4
PPG4 pin
INTTC4 interrupt request
TMP86C845UG
TMP86C845UG
8.3.9
Warm-Up Counter Mode
In this mode, the warm-up period time is obtained to assure oscillation stability when the system clocking is switched between the high-frequency and low-frequency. The timer counter 3 and 4 are cascadable to form a 16-bit TimerCouter. The warm-up counter mode has two types of mode; switching from the high-frequency to low-frequency, and vice-versa.
Note 1: In the warm-up counter mode, fix TCiCR to 0. If not fixed, the PDOi, PWMi and PPGi pins may output pulses. Note 2: In the warm-up counter mode, only upper 8 bits of the timer register TTREG4 and 3 are used for match detection and lower 8 bits are not used. Note 3: i = 3, 4
8.3.9.1
Low-Frequency Warm-up Counter Mode (NORMAL1 NORMAL2 SLOW2 SLOW1)
In this mode, the warm-up period time from a stop of the low-frequency clock fs to oscillation stability is obtained. Before starting the timer, set SYSCR2 to 1 to oscillate the low-frequency clock. When a match between the up-counter and the timer register (TTREG4, 3) value is detected after the timer is started by setting TC4CR to 1, the counter is cleared by generating the INTTC4 interrupt request. After stopping the timer in the INTTC4 interrupt service routine, set SYSCR2 to 1 to switch the system clock from the high-frequency to low-frequency, and then clear of SYSCR2 to 0 to stop the high-frequency clock.
Table 8-8 Setting Time of Low-Frequency Warm-Up Counter Mode (fs = 32.768 kHz)
Maximum Time Setting (TTREG4, 3 = 0100H) 7.81 ms Maximum Time Setting (TTREG4, 3 = FF00H) 1.99 s
Example :After checking low-frequency clock oscillation stability with TC4 and 3, switching to the SLOW1 mode
SET LD LD LD DI SET EI SET : PINTTC4: CLR SET (TC4CR).3 : (TC4CR).3 (SYSCR2).5 : Stops TC4 and 3. : SYSCR2 1 (Switches the system clock to the low-frequency clock.) : SYSCR2 0 (Stops the high-frequency clock.) (EIRH). 1 (SYSCR2).6 (TC3CR), 43H (TC4CR), 05H (TTREG3), 8000H : SYSCR2 1 : Sets TFF3=0, source clock fs, and 16-bit mode. : Sets TFF4=0, and warm-up counter mode. : Sets the warm-up time. (The warm-up time depends on the oscillator characteristic.) : IMF 0 : Enables the INTTC4. : IMF 1 : Starts TC4 and 3.
CLR RETI : VINTTC4: DW
(SYSCR2).7
: PINTTC4 : INTTC4 vector table
Page 83
8. 8-Bit TimerCounter (TC3, TC4)
8.1 Configuration TMP86C845UG
8.3.9.2
High-Frequency Warm-Up Counter Mode (SLOW1 SLOW2 NORMAL2 NORMAL1)
In this mode, the warm-up period time from a stop of the high-frequency clock fc to the oscillation stability is obtained. Before starting the timer, set SYSCR2 to 1 to oscillate the high-frequency clock. When a match between the up-counter and the timer register (TTREG4, 3) value is detected after the timer is started by setting TC4CR to 1, the counter is cleared by generating the INTTC4 interrupt request. After stopping the timer in the INTTC4 interrupt service routine, clear SYSCR2 to 0 to switch the system clock from the low-frequency to high-frequency, and then SYSCR2 to 0 to stop the low-frequency clock.
Table 8-9 Setting Time in High-Frequency Warm-Up Counter Mode
Minimum time (TTREG4, 3 = 0100H) 16 s Maximum time (TTREG4, 3 = FF00H) 4.08 ms
Example :After checking high-frequency clock oscillation stability with TC4 and 3, switching to the NORMAL1 mode
SET LD LD LD (SYSCR2).7 (TC3CR), 63H (TC4CR), 05H (TTREG3), 0F800H : SYSCR2 1 : Sets TFF3=0, source clock fs, and 16-bit mode. : Sets TFF4=0, and warm-up counter mode. : Sets the warm-up time. (The warm-up time depends on the oscillator characteristic.) : IMF 0 (EIRH). 1 : Enables the INTTC4. : IMF 1 (TC4CR).3 : (TC4CR).3 (SYSCR2).5 : Stops the TC4 and 3. : SYSCR2 0 (Switches the system clock to the high-frequency clock.) : SYSCR2 0 (Stops the low-frequency clock.) : Starts the TC4 and 3.
DI SET EI SET : PINTTC4: CLR CLR
CLR
(SYSCR2).6
RETI : VINTTC4: DW : PINTTC4 : INTTC4 vector table
Page 84
TMP86C845UG
9. Synchronous Serial Interface (SIO)
The serial interfaces connect to an external device via SI, SO, and SCK pins. When these pins are used as serial interface, the output latches for each port should be set to "1".
9.1 Configuration
Internal data bus
SIOCR1
SIOSR
SIOTDB
Shift clock Control circuit MSB/LSB selection
Shift register on transmitter
Port (Note) Port (Note)
SO pin
(Serial data output)
SI pin
Shift register on receiver
SIORDB
(Serial data input)
To BUS
Port (Note)
SCK pin
INTSIO
interrupt
Internal clock input
(Serial data output)
Note: Set the register of port correctly for the port assigned as serial interface pins. For details, see the description of the input/output port control register.
Figure 9-1 Synchronous Serial Interface (SIO)
Page 85
9. Synchronous Serial Interface (SIO)
9.2 Control TMP86C845UG
9.2 Control
The SIO is controlled using the serial interface control register (SIOCR1). The operating status of the serial interface can be inspected by reading the status register (SIOCR1). Serial Interface Control Register
SIOCR1 (0026H) 7 SIOS 6 SIOINH 5 SIOM 4 3 SIODIR 2 1 SCK 0 (Initial value: 0000 0000)
SIOS SIOINH
Specify start/stop of transfer Forcibly stops transfer (Note 1)
0: Stop 1: Start 0: - 1: Forcibly stop (Automatically cleared to "0" after stopping) 00: Transmit mode 01: Receive mode 10: Transmit/receive mode 11: Reserved 0: MSB (Transfer beginning with bit7) 1: LSB (Transfer beginning with bit0) NORMAL1/2 or IDLE1/2 modes TBTCR = "0" 000 001 fc/212 fc/28 fc/27 fc/26 fc/25 fc/24 fc/23 TBTCR = "1" fs/24 fc/28 fc/27 fc/26 fc/25 fc/24 fc/23 External clock (Input from SCK pin) SLOW/SLEEP mode fs/24 Reserved Reserved Reserved Reserved Reserved Reserved
SIOM
Selects transfer mode
SIODIR
Selects direction of transfer
R/W
SCK
Selects serial clock
010 011 100 101 110 111
Note 1: When SIOCR1 is set to "1", SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized. Note 2: Transfer mode, direction of transfer and serial clock must be select during the transfer is stopping (when SIOSR "0"). Note 3: fc: High-frequency clock [Hz], fs: Low-frequency clock [Hz], *: Don't care
Page 86
TMP86C845UG
Serial Interface Status Register
SIOSR (0027H) 7 SIOF 6 SEF 5 TXF 4 RXF 3 TXERR 2 RXERR 1 0 (Initial value: 0010 00**)
SIOF SEF TXF RXF
Serial transfer operation status monitor Number of clocks monitor Transmit buffer empty flag Receive buffer full flag
0: Transfer finished 1: Transfer in progress 0: 8 clocks 1: 1 to 7 clocks 0: Data exists in transmit buffer 1: No data exists in transmit buffer 0: No data exists in receive buffer 1: Data exists in receive buffer Read 0: - (No error exist) 1: Transmit buffer under run occurs in an external clock mode Write 0: Clear the flag 1: - (A write of "1" to this bit is ignored) Read 0: - (No error exist) 1: Receive buffer over run occurs in an external clock mode Write 0: Clear the flag 1: - (A write of "1" to this bit is ignored)
Read only
TXERR
Transfer operation error flag
R/W
RXERR
Receive operation error flag
Note 1: The operation error flag (TXERR and RXERR) are not automatically cleared by stopping transfer with SIOCR1 "0". Therefore, set these bits to "0" for clearing these error flag. Or set SIOCR1 to "1". Note 2: *: Don't care
Receive buffer register
SIORDB (0028H) 7 6 5 4 3 2 1 0 Read only (Initial value: 0000 0000)
Transmit buffer register
SIOTDB (0028H) 7 6 5 4 3 2 1 0 Write only (Initial value: **** ****)
Note 1: SIOTDB is write only register. A bit manipulation should not be performed on the transmit buffer register using a readmodify-write instruction. Note 2: The SIOTDB should be written after checking SIOSR "1". When SIOSR is "0", the writing data can't be transferred to SIOTDB even if write instruction is executed to SIOTDB Note 3: *: Don't care
Page 87
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
9.3 Function
9.3.1 Serial clock
Clock source
The serial clock can be selected by using SIOCR1. When the serial clock is changed, the writing instruction to SIOCR1 should be executed while the transfer is stopped (when SIOSR "0") (1) Internal clock Setting the SIOCR1 to other than "111B" outputs the clock (shown in " Table 9-1 Serial Clock Rate (fc = 16 MHz, fs = 32.768kHz) ") as serial clock outputs from SCK pin. At the before beginning or finishing of a transfer, SCK pin is kept in high level. When writing (in the transmit mode) or reading (in the receive mode) data can not follow the serial clock rate, an automatic-wait function is executed to stop the serial clock automatically and hold the next shift operation until reading or writing is completed (shown in " Figure 9-2 Automatic-wait Function (Example of transmit mode) "). The maximum time from releasing the automatic-wait function by reading or writing a data is 1 cycle of the selected serial clock until the serial clock comes out from SCK pin.
9.3.1.1
SIOCR1
Automatically wait
SCK pin output
SO pin SIOTDB
A
A7 A6 A5 A4 A3 A2 A1
A0
B7 B6 B5 B4 B3 B2 B1 B0 B
Automatic wait is released by writing SIOTDB
Figure 9-2 Automatic-wait Function (Example of transmit mode)
Table 9-1 Serial Clock Rate (fc = 16 MHz, fs = 32.768kHz)
NORMAL1/2, IDLE1/2 Mode TBTCR = "0" SCK 000 001 010 011 100 101 110 Serial Clock fc/212 fc/28 fc/27 fc/26 fc/25 fc/24 fc/23 Baud Rate 3.906 kbps 62.5 kbps 125 kbps 250 kbps 500 kbps 1.00 Mbps 2.00 Mbps TBTCR = "1" Serial Clock Serial Clock fs/24 fc/28 fc/27 fc/26 fc/25 fc/24 fc/23 Baud Rate 2048 bps 62.5 kbps 125 kbps 250 kbps 500 kbps 1.00 Mbps 2.00 Mbps fs/24 Reserved Reserved Reserved Reserved Reserved Reserved 2048 bps - - - - - Baud Rate SLOW1/2, SLEEP1/2 Mode
Page 88
TMP86C845UG
(2)
External clock When an external clock is selected by setting SIOCR1 to "111B", the clock via the SCK pin from an external source is used as the serial clock. To ensure shift operation, the serial clock pulse width must be 4/fc or more for both "H" and "L" levels.
SCK pin
tSCKL
tSCKH
tSCKL, tSCKH > 4/fc
Figure 9-3 External Clock
9.3.1.2 Shift edge
The leading edge is used to transmit data, and the trailing edge is used to receive data. (1)
Leading edge shift Data is shifted on the leading edge of the serial clock (falling edge of the SCK pin input/output).
(2)
Trailing edge shift Data is shifted on the trailing edge of the serial clock (rising edge of the SCK pin input/output).
SIOCR1
SCK pin
Shift register
01234567
*0123456 Shift out
**012345
***01234
****0123
*****012
******01
*******0
********
SO pin
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
(a) Leading edge shift (Example of MSB transfer)
SIOCR1
SCK pin
SI pin Shift register
Bit7 ******** 7*******
Bit6 67******
Bit5 567*****
Bit4 4567****
Bit3 34567***
Bit2
Bit1 234567**
Bit0 1234567* 01234567
(b) Trailing edge shift (Example of MSB transfer)
Figure 9-4 Shift Edge
Page 89
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
9.3.2
Transfer bit direction
Transfer data direction can be selected by using SIOCR1. The transfer data direction can't be set individually for transmit and receive operations. When the data direction is changed, the writing instruction to SIOCR1 should be executed while the transfer is stopped (when SIOCR1= "0")
SIOCR1
SCK pin
SIOTDB SO pin
A Shift out A7 A6 A5 A4 A3 A2 A1 A0
(a) MSB transfer
SIOCR1
SCK pin
SIOTDB SO pin
A Shift out A0 A1 A2 A3 A4 A5 A6 A7
(b) LSB transfer
Figure 9-5 Transfer Bit Direction (Example of transmit mode)
9.3.2.1 Transmit mode
(1) MSB transmit mode MSB transmit mode is selected by setting SIOCR1 to "0", in which case the data is transferred sequentially beginning with the most significant bit (Bit7). (2) LSB transmit mode LSB transmit mode is selected by setting SIOCR1 to "1", in which case the data is transferred sequentially beginning with the least significant bit (Bit0).
9.3.2.2
Receive mode
(1) MSB receive mode MSB receive mode is selected by setting SIOCR1 to "0", in which case the data is received sequentially beginning with the most significant bit (Bit7).
Page 90
TMP86C845UG
(2)
LSB receive mode LSB receive mode is selected by setting SIOCR1 to "1", in which case the data is received sequentially beginning with the least significant bit (Bit0).
9.3.2.3
Transmit/receive mode
(1) MSB transmit/receive mode MSB transmit/receive mode are selected by setting SIOCR1 to "0" in which case the data is transferred sequentially beginning with the most significant bit (Bit7) and the data is received sequentially beginning with the most significant (Bit7). (2) LSB transmit/receive mode LSB transmit/receive mode are selected by setting SIOCR1 to "1", in which case the data is transferred sequentially beginning with the least significant bit (Bit0) and the data is received sequentially beginning with the least significant (Bit0).
9.3.3
Transfer modes
Transmit, receive and transmit/receive mode are selected by using SIOCR1.
9.3.3.1
Transmit mode
Transmit mode is selected by writing "00B" to SIOCR1. (1) Starting the transmit operation Transmit mode is selected by setting "00B" to SIOCR1. Serial clock is selected by using SIOCR1. Transfer direction is selected by using SIOCR1. When a transmit data is written to the transmit buffer register (SIOTDB), SIOSR is cleared to "0". After SIOCR1 is set to "1", SIOSR is set synchronously to "1" the falling edge of
SCK pin.
The data is transferred sequentially starting from SO pin with the direction of the bit specified by SIOCR1, synchronizing with the SCK pin's falling edge. SIOSR is kept in high level, between the first clock falling edge of SCK pin and eighth clock falling edge. SIOSR is set to "1" at the rising edge of pin after the data written to the SIOTDB is transferred to shift register, then the INTSIO interrupt request is generated, synchronizing with the next falling edge on SCK pin.
Note 1: In internal clock operation, when SIOCR1 is set to "1", transfer mode does not start without writing a transmit data to the transmit buffer register (SIOTDB). Note 2: In internal clock operation, when the SIOCR1 is set to "1", SIOTDB is transferred to shift register after maximum 1-cycle of serial clock frequency, then a serial clock is output from SCK pin. Note 3: In external clock operation, when the falling edge is input from SCK pin after SIOCR1 is set to "1", SIOTDB is transferred to shift register immediately.
Page 91
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
(2)
During the transmit operation When data is written to SIOTDB, SIOSR is cleared to "0". In internal clock operation, in case a next transmit data is not written to SIOTDB, the serial clock stops to "H" level by an automatic-wait function when all of the bit set in the SIOTDB has been transmitted. Automatic-wait function is released by writing a transmit data to SIOTDB. Then, transmit operation is restarted after maximum 1-cycle of serial clock. When the next data is written to the SIOTDB before termination of previous 8-bit data with SIOSR "1", the next data is continuously transferred after transmission of previous data. In external clock operation, after SIOSR is set to "1", the transmit data must be written to SIOTDB before the shift operation of the next data begins. If the transmit data is not written to SIOTDB, transmit error occurs immediately after shift operation is started. Then, INTSIO interrupt request is generated after SIOSR is set to "1".
(3)
Stopping the transmit operation There are two ways for stopping transmits operation. * The way of clearing SIOCR1. When SIOCR1 is cleared to "0", transmit operation is stopped after all transfer of the data is finished. When transmit operation is finished, SIOSR is cleared to "0" and SO pin is kept in high level. In external clock operation, SIOCR1 must be cleared to "0" before SIOSR is set to "1" by beginning next transfer. * The way of setting SIOCR1. Transmit operation is stopped immediately after SIOCR1 is set to "1". In this case, SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized.
Clearing SIOS
SIOCR1 SIOSR SIOSR
Start shift operation
Start shift operation
Start shift operation
SCK pin outout
Automatic wait
SO pin SIOSR INTSIO interrupt request SIOTDB
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0
C7 C6 C5 C4 C3 C2 C1 C0
A
B
C
Writing transmit Writing transmit data A data B
Writing transmit data C
Figure 9-6 Example of Internal Clock and MSB Transmit Mode
Page 92
TMP86C845UG
Writing transmit data
SIOCR1
Clearing SIOS
SIOSR
Start shift operation
Start shift operation
Start shift operation
SIOSR
SCK pin
SO pin
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0 C7 C6 C5 C4 C3 C2 C1 C0
SIOSR INTSIO interrupt request SIOTDB
A
B
C
Writing transmit data A
Writing transmit data B
Writing transmit data C
Figure 9-7 Exaple of External Clock and MSB Transmit Mode
SCK pin
SIOSR
SO pin
tSODH 4/fc < tSODH < 8/fc
Figure 9-8 Hold Time of the End of Transmit Mode
(4) Transmit error processing Transmit errors occur on the following situation. * Shift operation starts before writing next transmit data to SIOTDB in external clock operation. If transmit errors occur during transmit operation, SIOSR is set to "1" immediately after starting shift operation. Synchronizing with the next serial clock falling edge, INTSIO interrupt request is generated. If shift operation starts before writing data to SIOTDB after SIOCR1 is set to "1", SIOSR is set to "1" immediately after shift operation is started and then INTSIO interrupt request is generated. SIO pin is kept in high level when SIOSR is set to "1". When transmit error occurs, transmit operation must be forcibly stop by writing SIOCR1 to "1". In this case, SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized.
Page 93
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
SIOCR1 SIOSR SIOSR
SCK pin
Start shift operation
Start shift operation
Start shift operation
SO pin SIOSR SIOSR INTSIO interrupt request SIOTDB
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0
A
B
Unknown
SIOCR1
Writing transmit data A
Writing transmit data B
Figure 9-9 Example of Transmit Error Processingme
9.3.3.2 Receive mode
The receive mode is selected by writing "01B" to SIOCR. (1) Starting the receive operation Receive mode is selected by setting "01" to SIOCR1. Serial clock is selected by using SIOCR1. Transfer direction is selected by using SIOCR1. After SIOCR1 is set to "1", SIOSR is set synchronously to "1" the falling edge of SCK pin. Synchronizing with the SCK pin's rising edge, the data is received sequentially from SI pin with the direction of the bit specified by SBIDIR. SIOSR is kept in high level, between the first clock falling edge of SCK pin and eighth clock falling edge. When 8-bit data is received, the data is transferred to SIORDB from shift register. INTSIO interrupt request is generated and SIOSR is set to "1"
Note: In internal clock operation, when the SIOCR1 is set to "1", the serial clock is generated from SCK pin after maximum 1-cycle of serial clock frequency.
(2)
During the receive operation The SIOSR is cleared to "0" by reading a data from SIORDB. In the internal clock operation, the serial clock stops to "H" level by an automatic-wait function when the all of the 8-bit data has been received. Automatic-wait function is released by reading a received data from SIORDB. Then, receive operation is restarted after maximum 1-cycle of serial clock. In external clock operation, after SIOSR is set to "1", the received data must be read from SIORDB, before the next data shift-in operation is finished. Page 94
TMP86C845UG
If received data is not read out from SIORDB receive error occurs immediately after shift operation is finished. Then INTSIO interrupt request is generated after SIOSR is set to "1". (3) Stopping the receive operation There are two ways for stopping the receive operation. * The way of clearing SIOCR1. When SIOCR1 is cleared to "0", receive operation is stopped after all of the data is finished to receive. When receive operation is finished, SIOSR is cleared to "0". In external clock operation, SIOCR1 must be cleared to "0" before SIOSR is set to "1" by starting the next shift operation. * The way of setting SIOCR1. Receive operation is stopped immediately after SIOCR1 is set to "1". In this case, SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized.
Clearing SIOS
SIOCR1
SIOSR
Start shift operation
Start shift operation
Start shift operation
SIOSR
SCK pin
Automatic wait
SI pin SIOSR INTSIO interrupt request SIORDB
A7 A6 A5 A4 A3 A2 A1
A0
B7 B6 B5 B4 B3 B2 B1 B0
C7 C6 C5 C4 C3 C2 C1 C0
A
B
C
Writing transmit data A
Writing transmit data B
Writing transmit data C
Figure 9-10 Example of Internal Clock and MSB Receive Mode
Page 95
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
Reading received data
SIOCR1 SIOSR
Clearing SIOS
Start shift operation
Start shift operation
Start shift operation
SIOSR
SCK pin
SI pin SIOSR INTSIO interrupt request SIORDB
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0 C7 C6 C5 C4 C3 C2 C1 C0
A
B
C
Writing transmit data A
Writing transmit data B
Writing transmit data C
Figure 9-11 Example of External Clock and MSB Receive Mode
(4) Receive error processing Receive errors occur on the following situation. To protect SIORDB and the shift register contents, the received data is ignored while the SIOSR is "1". * Shift operation is finished before reading out received data from SIORDB at SIOSR is "1" in an external clock operation. If receive error occurs, set the SIOCR1 to "0" for reading the data that received immediately before error occurence. And read the data from SIORDB. Data in shift register (at errors occur) can be read by reading the SIORDB again. When SIOSR is cleared to "0" after reading the received data, SIOSR is cleared to "0". After clearing SIOCR1 to "0", when 8-bit serial clock is input to SCK pin, receive operation is stopped. To restart the receive operation, confirm that SIOSR is cleared to "0". If the receive error occurs, set the SIOCR1 to "1" for stopping the receive operation immediately. In this case, SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized.
Page 96
TMP86C845UG
SIOCR1 SIOSR SIOSR
Start shift operation
Start shift operation
Start shift operation
SCK pin
SI pin SIOSR SIOSR INTSIO interrupt request SIORDB
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0 C7 C6 C5 C4 C3 C2 C1 C0
Write a "0" after reading the received data when a receive error occurs.
A
B
Writing transmit data A
Writing transmit data B
Figure 9-12 Example of Receive Error Processing
Note: If receive error is not corrected, an interrupt request does not generate after the error occurs.
9.3.3.3
Transmit/receive mode
The transmit/receive mode are selected by writing "10" to SIOCR1. (1) Starting the transmit/receive operation Transmit/receive mode is selected by writing "10B" to SIOCR1. Serial clock is selected by using SIOCR1. Transfer direction is selected by using SIOCR1. When a transmit data is written to the transmit buffer register (SIOTDB), SIOSR is cleared to "0". After SIOCR1 is set to "1", SIOSR is set synchronously to the falling edge of SCK pin. The data is transferred sequentially starting from SO pin with the direction of the bit specified by SIOCR1, synchronizing with the SCK pin's falling edge. And receiving operation also starts with the direction of the bit specified by SIOCR1, synchronizing with the SCK pin's rising edge. SIOSR is kept in high level between the first clock falling edge of SCK pin and eighth clock falling edge. SIOSR is set to "1" at the rising edge of SCK pin after the data written to the SIOTDB is transferred to shift register. When 8-bit data has been received, the received data is transferred to SIORDB from shift register, then the INTSIO interrupt request occurs, synchronizing with setting SIOSR to "1".
Note 1: In internal clock operation, when the SIOCR1 is set to "1", SIOTDB is transferred to shift register after maximum 1-cycle of serial clock frequency, then a serial clock is output from SCK pin. Note 2: In external clock operation, when the falling edge is input from SCK pin after SIOCR1 is set to "1", SIOTDB is transferred to shift register immediately. When the rising edge is input from SCK pin, receive operation also starts.
Page 97
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
(2)
During the transmit/receive operation When data is written to SIOTDB, SIOSR is cleared to "0" and when a data is read from SIORDB, SIOSR is cleared to "0". In internal clock operation, in case of the condition described below, the serial clock stops to "H" level by an automatic-wait function when all of the bit set in the data has been transmitted. * Next transmit data is not written to SIOTDB after reading a received data from SIORDB. * Received data is not read from SIORDB after writing a next transmit data to SIOTDB. * Neither SIOTDB nor SIORDB is accessed after transmission. The automatic wait function is released by writing the next transmit data to SIOTDB after reading the received data from SIORDB, or reading the received data from SIORDB after writing the next data to SIOTDB. Then, transmit/receive operation is restarted after maximum 1 cycle of serial clock. In external clock operation, reading the received data from SIORDB and writing the next data to SIOTDB must be finished before the shift operation of the next data begins. If the transmit data is not written to SIOTDB after SIOSR is set to "1", transmit error occurs immediately after shift operation is started. When the transmit error occurred, SIOSR is set to "1". If received data is not read out from SIORDB before next shift operation starts after setting SIOSR to "1", receive error occurs immediately after shift operation is finished. When the receive error has occurred, SIOSR is set to "1".
(3)
Stopping the transmit/receive operation There are two ways for stopping the transmit/receive operation. * The way of clearing SIOCR1. When SIOCR1 is cleared to "0", transmit/receive operation is stopped after all transfer of the data is finished. When transmit/receive operation is finished, SIOSR is cleared to "0" and SO pin is kept in high level. In external clock operation, SIOCR1 must be cleared to "0" before SIOSR is set to "1" by beginning next transfer. * The way of setting SIOCR1. Transmit/receive operation is stopped immediately after SIOCR1 is set to "1". In this case, SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized.
Page 98
TMP86C845UG
Clearing SIOS
SIOCR1 SIOSR SIOSR
SCK pin output
Start shift operation
Start shift operation
Start shift operation
Automatic wait
Automatic wait
SO pin SI pin INTSIO interrupt request SIOSR SIOTDB
A7 A6 A5 A4 A3 A2 A1 D7 D6 D5 D4 D3 D2 D1
A0 D0
B7 B6 B5 B4 B3 B2 B1 E7 E6 E5 E4 E3 E2 E1
B0 E0
C7 C6 C5 C4 C3 C2 C1 C0 F7 F6 F5 F4 F3 F2 F1 F0
A
B
C
Writing transmit data A
SIOSR SIORDB
Writing transmit data B
Writing transmit data C
D
E
F
Reading received data D
Reading received data E
Reading received data F
Figure 9-13 Example of Internal Clock and MSB Transmit/Receive Mode
Page 99
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
Reading received data Writing transmit data
SIOCR1 SIOSR
Clearing SIOS
Start shift operation
Start shift operation
Start shift operation
SIOSR
SCK pin output
SO pin SI pin INTSIO interrupt request SIOSR
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0 C7 C6 C5 C4 C3 C2 C1 C0
D7 D6 D5 D4 D3 D2 D1 D0 E7 E6 E5 E4 E3 E2 E1 E0 F7 F6 F5 F4 F3 F2 F1 F0
SIOTDB
A
B
C
Writing transmit data A
SIOSR
Writing transmit data B
Writing transmit data C
SIORDB
D
E
F
Reading received data D
Reading received data E
Reading received data F
Figure 9-14 Example of External Clock and MSB Transmit/Receive Mode
(4) Transmit/receive error processing Transmit/receive errors occur on the following situation. Corrective action is different, which errors occur transmits or receives. (a) Transmit errors Transmit errors occur on the following situation. * Shift operation starts before writing next transmit data to SIOTDB in external clock operation. If transmit errors occur during transmit operation, SIOSR is set to "1" immediately after starting shift operation. And INTSIO interrupt request is generated after all of the 8-bit data has been received. If shift operation starts before writing data to SIOTDB after SIOCR1 is set to "1", SIOSR is set immediately after starting shift operation. And INTSIO interrupt request is generated after all of the 8-bit data has been received. SO pin is kept in high level when SIOSR is set to "1". When transmit error occurs, transmit operation must be forcibly stop by writing SIOCR1 to "1" after the received data is read from SIORDB. In this case, SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized.
Page 100
TMP86C845UG
SIOCR1 SIOSR SIOSR
SCK pin output
Start shift operation
Start shift operation
Start shift operation
SO pin SI pin INTSIO interrupt request SIOSR SIOSR
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0
D7 D6 D5 D4 D3 D2 D1 D0 E7 E6 E5 E4 E3 E2 E1 E0 F7 F6 F5 F4 F3 F2 F1 F0
SIOTDB
A
B
Unknown
Writing transmit data A
SIOSR
Writing transmit data B
SIORDB
D
E
F
Reading received data D
SIOCR1
Reading received data E
Reading received data F
Figure 9-15 Example of Transmit/Receive (Transmit) Error Processing
(b) Receive errors Receive errors occur on the following situation. To protect SIORDB and the shift register contents, the received data is ignored while the SIOSR is "1". * Shift operation is finished before reading out received data from SIORDB at SIOSR is "1" in an external clock operation. If receive error occurs, set the SIOCR1 to "0" for reading the data that received immediately before error occurence. And read the data from SIORDB. Data in shift register (at errors occur) can be read by reading the SIORDB again. When SIOSR is cleared to "0" after reading the received data, SIOSR is cleared to "0". After clearing SIOCR1 to "0", when 8-bit serial clock is input to SCK pin, receive operation is stopped. To restart the receive operation, confirm that SIOSR is cleared to "0". If the received error occurs, set the SIOCR1 to "1" for stopping the receive operation immediately. In this case, SIOCR1, SIOSR register, SIORDB register and SIOTDB register are initialized.
Page 101
9. Synchronous Serial Interface (SIO)
9.3 Function TMP86C845UG
SIOCR1 SIOSR
Start shift operation
Start shift operation
Start shift operation
SIOSR
SCK pin output
SO pin SI pin INTSIO interrupt request SIOSR
A7 A6 A5 A4 A3 A2 A1 A0 B7 B6 B5 B4 B3 B2 B1 B0 C7 C6 C5 C4 C3
D7 D6 D5 D4 D3 D2 D1 D0 E7 E6 E5 E4 E3 E2 E1 E0 F7 F6 F5 F4 F3 F2 F1 F0
SIOTDB
A
B
C
Unknown
Writing transmit data A
SIOSR
Writing transmit data B
Writing transmit data C
SIOSR SIORDB
D
E
OOH
Reading received data D
SIOCR1
Reading received data E
Figure 9-16 Example of Transmit/Receive (Receive) Error Processing
Note: If receive error is not corrected, an interrupt request does not generate after the error occurs.
SCK pin
SIOSR
SO pin
tSODH 4/fc < tSODH < 8/fc
Figure 9-17 Hold Time of the End of Transmit/Receive Mode
Page 102
TMP86C845UG
10. 10-bit AD Converter (ADC)
The TMP86C845UG have a 10-bit successive approximation type AD converter.
10.1 Configuration
The circuit configuration of the 10-bit AD converter is shown in Figure 10-1. It consists of control register ADCCR1 and ADCCR2, converted value register ADCDR1 and ADCDR2, a DA converter, a sample-hold circuit, a comparator, and a successive comparison circuit.
DA converter
VAREF AVSS
R/2
AVDD
R Reference voltage
R/2
Analog input multiplexer
AIN0
Sample hold circuit
A
Y 10 Analog comparator
AIN7
n S EN IREFON 4 SAIN ADRS AINDS
Successive approximate circuit Shift clock Control circuit 2 AMD 3 ACK ADCCR2 8 ADCDR1 2 INTADC
EOCF ADBF
ADCCR1
ADCDR2
AD converter control register 1, 2
AD conversion result register 1, 2
Note: Before using AD converter, set appropriate value to I/O port register conbining a analog input port. For details, see the section on "I/O ports".
Figure 10-1 10-bit AD Converter
Page 103
10. 10-bit AD Converter (ADC)
10.2 Register configuration TMP86C845UG
10.2 Register configuration
The AD converter consists of the following four registers: 1. AD converter control register 1 (ADCCR1) This register selects the analog channels and operation mode (Software start or repeat) in which to perform AD conversion and controls the AD converter as it starts operating. 2. AD converter control register 2 (ADCCR2) This register selects the AD conversion time and controls the connection of the DA converter (Ladder resistor network). 3. AD converted value register 1 (ADCDR1) This register used to store the digital value fter being converted by the AD converter. 4. AD converted value register 2 (ADCDR2) This register monitors the operating status of the AD converter. AD Converter Control Register 1
ADCCR1 (001CH) 7 ADRS 6 AMD 5 4 AINDS 3 2 SAIN 1 0 (Initial value: 0001 0000)
ADRS
AD conversion start
0: 1: 00: 01: 10: 11: 0: 1: 0000: 0001: 0010: 0011: 0100: 0101: 0110: 0111: 1000: 1001: 1010: 1011: 1100: 1101: 1110: 1111:
AD conversion start AD operation disable Software start mode Reserved Repeat mode Analog input enable Analog input disable AIN0 AIN1 AIN2 AIN3 AIN4 AIN5 AIN6 AIN7 Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved
AMD
AD operating mode
AINDS
Analog input control
R/W
SAIN
Analog input channel select
Note 1: Select analog input channel during AD converter stops (ADCDR2 = "0"). Note 2: When the analog input channel is all use disabling, the ADCCR1 should be set to "1". Note 3: During conversion, Do not perform port output instruction to maintain a precision for all of the pins because analog input port use as general input port. And for port near to analog input, Do not input intense signaling of change. Note 4: The ADCCR1 is automatically cleared to "0" after starting conversion. Note 5: Do not set ADCCR1 newly again during AD conversion. Before setting ADCCR1 newly again, check ADCDR2 to see that the conversion is completed or wait until the interrupt signal (INTADC) is generated (e.g., interrupt handling routine). Note 6: After STOP or SLOW/SLEEP mode are started, AD converter control register1 (ADCCR1) is all initialized and no data can be written in this register. Therfore, to use AD converter again, set the ADCCR1 newly after returning to NORMAL1 or NORMAL2 mode.
Page 104
TMP86C845UG
AD Converter Control Register 2
ADCCR2 (001DH) 7 6 5 IREFON 4 "1" 3 2 ACK 1 0 "0" (Initial value: **0* 000*)
IREFON
DA converter (Ladder resistor) connection control
0: 1: 000: 001: 010: 011: 100: 101: 110: 111:
Connected only during AD conversion Always connected 39/fc Reserved 78/fc 156/fc 312/fc 624/fc 1248/fc Reserved
ACK
AD conversion time select (Refer to the following table about the conversion time)
R/W
Note 1: Always set bit0 in ADCCR2 to "0" and set bit4 in ADCCR2 to "1". Note 2: When a read instruction for ADCCR2, bit6 to 7 in ADCCR2 read in as undefined data. Note 3: After STOP or SLOW/SLEEP mode are started, AD converter control register2 (ADCCR2) is all initialized and no data can be written in this register. Therfore, to use AD converter again, set the ADCCR2 newly after returning to NORMAL1 or NORMAL2 mode.
Table 10-1 ACK setting and Conversion time
Condition ACK 000 001 010 011 100 101 110 111 78/fc 156/fc 312/fc 624/fc 1248/fc 19.5 s 39.0 s 78.0 s 19.5 s 39.0 s 78.0 s 156.0 s Conversion time 39/fc 16 MHz 8 MHz 4 MHz 2 MHz 19.5 s Reserved 19.5 s 39.0 s 78.0 s 156.0 s Reserved 39.0 s 78.0 s 156.0 s 15.6 s 31.2 s 62.4 s 124.8 s 15.6 s 31.2 s 62.4 s 124.8 s 31.2 s 62.4 s 124.8 s 10 MHz 5 MHz 2.5 MHz 15.6 s
Note 1: Setting for "-" in the above table are inhibited.
fc: High Frequency oscillation clock [Hz]
Note 2: Set conversion time setting should be kept more than the following time by Analog reference voltage (VAREF) .
VAREF = 4.5 to 5.5 V VAREF = 2.7 to 5.5 V 15.6 s and more 31.2 s and more
AD Converted value Register 1
ADCDR1 (001FH) 7 AD09 6 AD08 5 AD07 4 AD06 3 AD05 2 AD04 1 AD03 0 AD02 (Initial value: 0000 0000)
AD Converted value Register 2
ADCDR2 (001EH) 7 AD01 6 AD00 5 EOCF 4 ADBF 3 2 1 0 (Initial value: 0000 ****)
Page 105
10. 10-bit AD Converter (ADC)
10.2 Register configuration TMP86C845UG
EOCF ADBF
AD conversion end flag AD conversion BUSY flag
0: 1: 0: 1:
Before or during conversion Conversion completed During stop of AD conversion During AD conversion
Read only
Note 1: The ADCDR2 is cleared to "0" when reading the ADCDR1. Therfore, the AD conversion result should be read to ADCDR2 more first than ADCDR1. Note 2: The ADCDR2 is set to "1" when AD conversion starts, and cleared to "0" when AD conversion finished. It also is cleared upon entering STOP mode or SLOW mode . Note 3: If a read instruction is executed for ADCDR2, read data of bit3 to bit0 are unstable.
Page 106
TMP86C845UG
10.3 Function
10.3.1 Software Start Mode
After setting ADCCR1 to "01" (software start mode), set ADCCR1 to "1". AD conversion of the voltage at the analog input pin specified by ADCCR1 is thereby started. After completion of the AD conversion, the conversion result is stored in AD converted value registers (ADCDR1, ADCDR2) and at the same time ADCDR2 is set to 1, the AD conversion finished interrupt (INTADC) is generated. ADRS is automatically cleared after AD conversion has started. Do not set ADCCR1 newly again (Restart) during AD conversion. Before setting ADRS newly again, check ADCDR2 to see that the conversion is completed or wait until the interrupt signal (INTADC) is generated (e.g., interrupt handling routine).
AD conversion start ADCCR1 AD conversion start
ADCDR2
ADCDR1 status
Indeterminate
1st conversion result
2nd conversion result EOCF cleared by reading conversion result
ADCDR2
INTADC interrupt request ADCDR1 Conversion result read Conversion result read Conversion result read Conversion result read
ADCDR2
Figure 10-2 Software Start Mode 10.3.2 Repeat Mode
AD conversion of the voltage at the analog input pin specified by ADCCR1 is performed repeatedly. In this mode, AD conversion is started by setting ADCCR1 to "1" after setting ADCCR1 to "11" (Repeat mode). After completion of the AD conversion, the conversion result is stored in AD converted value registers (ADCDR1, ADCDR2) and at the same time ADCDR2 is set to 1, the AD conversion finished interrupt (INTADC) is generated. In repeat mode, each time one AD conversion is completed, the next AD conversion is started. To stop AD conversion, set ADCCR1 to "00" (Disable mode) by writing 0s. The AD convert operation is stopped immediately. The converted value at this time is not stored in the AD converted value register.
Page 107
10. 10-bit AD Converter (ADC)
10.3 Function TMP86C845UG
ADCCR1 AD conversion start ADCCR1
"11"
"00"
Conversion operation
1st conversion result
2nd conversion result
3rd conversion result
AD convert operation suspended. Conversion result is not stored.
3rd conversion result
ADCDR1,ADCDR2
Indeterminate
1st conversion result
2nd conversion result
ADCDR2 EOCF cleared by reading conversion result
INTADC interrupt request ADCDR1 ADCDR2 Conversion result read Conversion result read Conversion result read Conversion result read
Conversion result read Conversion result read
Figure 10-3 Repeat Mode 10.3.3 Register Setting
1. Set up the AD converter control register 1 (ADCCR1) as follows: * Choose the channel to AD convert using AD input channel select (SAIN). * Specify analog input enable for analog input control (AINDS). * Specify AMD for the AD converter control operation mode (software or repeat mode). 2. Set up the AD converter control register 2 (ADCCR2) as follows: * Set the AD conversion time using AD conversion time (ACK). For details on how to set the conversion time, refer to Figure 10-1 and AD converter control register 2. * Choose IREFON for DA converter control. 3. After setting up (1) and (2) above, set AD conversion start (ADRS) of AD converter control register 1 (ADCCR1) to "1". If software start mode has been selected, AD conversion starts immediately. 4. After an elapse of the specified AD conversion time, the AD converted value is stored in AD converted value register 1 (ADCDR1) and the AD conversion finished flag (EOCF) of AD converted value register 2 (ADCDR2) is set to "1", upon which time AD conversion interrupt INTADC is generated. 5. EOCF is cleared to "0" by a read of the conversion result. However, if reconverted before a register read, although EOCF is cleared the previous conversion result is retained until the next conversion is completed.
Page 108
TMP86C845UG
Example :After selecting the conversion time 19.5 s at 16 MHz and the analog input channel AIN3 pin, perform AD conversion once. After checking EOCF, read the converted value, store the lower 2 bits in address 0009EH nd store the upper 8 bits in address 0009FH in RAM. The operation mode is software start mode.
: (port setting) : LD LD : : (ADCCR1) , 00100011B (ADCCR2) , 11011000B ;Set port register approrriately before setting AD converter registers. (Refer to section I/O port in details) ; Select AIN3 ;Select conversion time(312/fc) and operation mode
SET SLOOP : TEST JRS
(ADCCR1) . 7 (ADCDR2) . 5 T, SLOOP
; ADRS = 1(AD conversion start) ; EOCF= 1 ?
LD LD LD LD
A , (ADCDR2) (9EH) , A A , (ADCDR1) (9FH), A
; Read result data
; Read result data
10.4 STOP/SLOW Modes during AD Conversion
When standby mode (STOP or SLOW mode) is entered forcibly during AD conversion, the AD convert operation is suspended and the AD converter is initialized (ADCCR1 and ADCCR2 are initialized to initial value). Also, the conversion result is indeterminate. (Conversion results up to the previous operation are cleared, so be sure to read the conversion results before entering standby mode (STOP or SLOW mode).) When restored from standby mode (STOP or SLOW mode), AD conversion is not automatically restarted, so it is necessary to restart AD conversion. Note that since the analog reference voltage is automatically disconnected, there is no possibility of current flowing into the analog reference voltage.
Page 109
10. 10-bit AD Converter (ADC)
10.5 Analog Input Voltage and AD Conversion Result TMP86C845UG
10.5 Analog Input Voltage and AD Conversion Result
The analog input voltage is corresponded to the 10-bit digital value converted by the AD as shown in Figure 10-4.
3FFH 3FEH 3FDH AD conversion result 03H 02H 01H
VAREF AVSS
0
1
2
3 1021 1022 1023 1024 Analog input voltage
1024
Figure 10-4 Analog Input Voltage and AD Conversion Result (Typ.)
Page 110
TMP86C845UG
10.6 Precautions about AD Converter
10.6.1 Analog input pin voltage range
Make sure the analog input pins (AIN0 to AIN7) are used at voltages within VAREF to AVSS. If any voltage outside this range is applied to one of the analog input pins, the converted value on that pin becomes uncertain. The other analog input pins also are affected by that.
10.6.2 Analog input shared pins
The analog input pins (AIN0 to AIN7) are shared with input/output ports. When using any of the analog inputs to execute AD conversion, do not execute input/output instructions for all other ports. This is necessary to prevent the accuracy of AD conversion from degrading. Not only these analog input shared pins, some other pins may also be affected by noise arising from input/output to and from adjacent pins.
10.6.3 Noise Countermeasure
The internal equivalent circuit of the analog input pins is shown in Figure 10-5. The higher the output impedance of the analog input source, more easily they are susceptible to noise. Therefore, make sure the output impedance of the signal source in your design is 5 k or less. Toshiba also recommends attaching a capacitor external to the chip.
Internal resistance AINi Permissible signal source impedance
5 k (max) 5 k (typ)
Analog comparator
Internal capacitance
C = 22 pF (typ.)
DA converter
Note) i = 7 to 0
Figure 10-5
Analog Input Equivalent Circuit and Example of Input Pin Processing
Page 111
10. 10-bit AD Converter (ADC)
10.6 Precautions about AD Converter TMP86C845UG
Page 112
TMP86C845UG
11. Input/Output Circuitry
11.1 Control Pins
The input/output circuitries of the TMP86C845UG control pins are shown below.
Control Pin I/O Input/Output Circuitry Remarks
Osc. enable
fc VDD RO
Resonator connecting pins (high-frequency) Rf = 1.2 M (typ.) RO = 1.5 k (typ.)
VDD
XIN XOUT Input Output
Rf
XIN
XOUT XTEN fs VDD RO
Resonator connecting pins (Low-frequency) Rf = 6 M (typ.) RO = 220 k (typ.)
Osc. enable
XTIN XTOUT
Input Output
VDD R
Rf
XTIN
XTOUT VDD
RESET
Input Output
R
RIN
Hysteresis input Pull-up resistor RIN = 220 k (typ.) R = 100 (typ.)
VDD
TEST Input
R RIN
D1
Pull-down resistor RIN = 70 k (typ.) R = 100 (typ.)
Note 1: The TEST pin of the TMP86PM47/PH47 does not have a pull-down resistor and protect diode (D1). Fix the TEST pin at low-level in MCU mode. Note 2: The input circuitry of RESET pin of TMP86C845 is diffeernt from TMP86PM47/PH47's one.
Page 113
11. Input/Output Circuitry
11.2 Input/Output Ports TMP86C845UG
11.2 Input/Output Ports
Port I/O Input/Output Circuitry Remarks
Initial "High-Z"
VDD
Sink open drain output High current output Hysteresis input R = 100 (typ.)
P07 to P05 P00
I/O
Data output Input from output latch Pin input R
Initial "High-Z"
VDD
Sink open drain output High current output R = 100 (typ.)
P04 to P01
I/O
Data output Input from output latch Pin input R
Initial "High-Z" Data output
P15 P12 to P10 I/O
VDD
Tri-state I/O Hysteresis input R = 100 (typ.)
Disable R Pin input
Initial "High-Z" Data output
P17, P16 P14, P13 I/O
VDD
Tri-state I/O R = 100 (typ.)
Disable R Pin input
Initial "High-Z"
VDD
Sink open drain output High current output Hysteresis input R = 100 (typ.)
P2
I/O
Data output Input from output latch Pin input R
Note: In TMP86PM47/PH47, P04 to P01, P17, 16, P14 and P13 are hysteresis inputs.
Page 114
TMP86C845UG
Port
I/O
Input/Output Circuitry
Remarks
Initial "High-Z" Data output
P3 I/O
VDD
Tri-state I/O R = 100 (typ.)
Disable R Pin input
Initial "High-Z" Data output
P4 I/O
VDD
Tri-state I/O High current output (Nch) R = 100 (typ.)
Disable R Pin input
Page 115
11. Input/Output Circuitry
11.2 Input/Output Ports TMP86C845UG
Page 116
TMP86C845UG
12. Electrical Characteristics
12.1 Absolute Maximum Ratings
The absolute maximum ratings are rated values which must not be exceeded during operation, even for an instant. Any one of the ratings must not be exceeded. If any absolute maximum rating is exceeded, a device may break down or its performance may be degraded, causing it to catch fire or explode resulting in injury to the user. Thus, when designing products which include this device, ensure that no absolute maximum rating value will ever be exceeded.
(VSS = 0 V) Parameter Supply voltage Input voltage Output voltage Symbol VDD VIN VOUT IOUT1 Output current (Per 1 pin) IOUT2 IOUT3 Output current (Total) Power dissipation [Topr = 85C] Soldering temperature (Time) Storage temperature Operating temperature IOUT1 IOUT2 PD Tsld Tstg Topr P1, P3, P4 port P1, P3 port P0, P2, P4 port P1, P3 port P0, P2, P4 port Pins Rating -0.3 to 6.5 -0.3 to VDD + 0.3 -0.3 to VDD + 0.3 -1.8 3.2 30 60 80 250 260 (10 s) -55 to 125 -40 to 85 C mW mA V Unit
12.2 Recommended Operating Condition
The recommended operating conditions for a device are operating conditions under which it can be guaranteed that the device will operate as specified. If the device is used under operating conditions other than the recommended operating conditions (supply voltage, operating temperature range, specified AC/DC values etc.), malfunction may occur. Thus, when designing products which include this device, ensure that the recommended operating conditions for the device are always adhered to.
(VSS = 0 V, Topr = -40 to 85C) Parameter Symbol Pins fc = 8 MHz Supply voltage VDD fs = 32.768 kHz Condition NORMAL1, 2 mode IDLE0, 1, 2 mode SLOW1, 2 mode SLEEP0, 1, 2 mode STOP mode VIH1 Input high level VIH2 VIH3 VIL1 Input low level VIL2 VIL3 Clock frequency fc fs XIN, XOUT XTIN, XTOUT Except hysteresis input Hysteresis input Except hysteresis input Hysteresis input VDD 4.5 V VDD < 4.5 V VDD 4.5 V VDD < 4.5 V VDD = 2.7 V to 5.5 V 1.0 30.0 Min 2.7 5.5 Max Unit
2.7 2.0 VDD x 0.70 VDD x 0.75 VDD x 0.90
V VDD
VDD x 0.30 0 VDD x 0.25 VDD x 0.10 8.0 34.0 MHz kHz
Page 117
12. Electrical Characteristics
12.3 DC Characteristics TMP86C845UG
12.3 DC Characteristics
(VSS = 0 V, Topr = -40 to 85C) Parameter Hysteresis voltage Symbol VHS IIN1 Input current IIN2 IIN3 Input resistance RIN1 RIN2 ILO1 ILO2 VOH VOL Output low current IOL Supply current in NORMAL1, 2 mode Supply current in IDLE0, 1, 2 mode Supply current in SLOW1 mode Supply current in SLEEP1 mode Supply current in SLEEP0 mode Supply current in STOP mode Pins Hysteresis input TEST Sink open drain, Tri-state
RESET, STOP
Condition
Min -
Typ. 0.9
Max -
Unit V
VDD = 5.5 V VIN = 5.5 V/0 V
-
-
2
A
TEST pull-down
RESET pull-up
- 100 VDD = 5.5 V, VOUT = 5.5 V VDD = 5.5 V, VOUT = 5.5 V/0 V VDD = 4.5 V, VOH = -0.7 mA VDD = 4.5 V, VOL = 1.6 mA VDD = 4.5 V, VOL = 1.0 V VDD = 5.5 V VIN = 5.3 V/0.2 V fc = 8 MHz fs = 32.768 kHz - - 4.1 - - - - -
70 200 - - - - 20 4.0 2.8 6 4 4
- 450 2 2 - 0.4 -
k
Output leakage current Output high voltage
Sink open drain Tri-state Tri-state port Except XOUT, XTOUT, P0, P4, P2 port High current port (P0, P2, P4 port)
A V
mA 6.2 4.5 18 15 A - 13
IDD
VDD = 3.0 V VIN = 2.8 V/0.2 V fs = 32.768 kHz -
VDD = 5.5 V VIN = 5.3 V/0.2 V
-
0.5
10
Note 1: Typical values show those at Topr = 25C, VDD = 5 V Note 2: Input current (IIN1, IIN3): The current through pull-up or pull-down resistor is not included. Note 3: IDD does not include IREF current.
Page 118
TMP86C845UG
12.4 AD Conversion Characteristics
(VSS = 0.0 V, 4.5 V to 5.5 V, Topr = -40 to 85C) Parameter Analog reference voltage Power supply voltage of analog control circuit Analog reference voltage range Analog input voltage Power supply current of analog reference Voltage Non linearity error Zero point error Full scale error Total error VDD = AVDD = 5.0 V VSS = AVSS = 0.0 V VAREF = 5.0 V Symbol VAREF AVDD VAREF VAIN IREF VDD = AVDD = VAREF = 5.5 V VSS = AVSS = 0.0 V 3.5 VSS - - - - - Condition Min AVDD - 1.0 Typ. - VDD - - 0.6 - - - - - VAREF 1.0 2 2 2 2 LSB mA Max AVDD Unit
V
(VSS = 0.0 V, 2.7 V to 4.5 V, Topr = -40 to 85C) Parameter Analog reference voltage Power supply voltage of analog control circuit Analog reference voltage range Analog input voltage Power supply current of analog reference voltage Non linearity error Zero point error Full scale error Total error VDD = AVDD = 2.7 V VSS = AVSS = 0.0 V VAREF = 2.7 V Symbol VAREF AVDD VAREF VAIN IREF VDD = AVDD = VAREF = 4.5 V VSS = AVSS = 0.0 V 2.5 VSS - - - - - Condition Min AVDD - 1.0 Typ. - VDD - - 0.5 - - - - - VAREF 0.8 2 2 2 2 LSB mA Max AVDD Unit
V
Note 1: The total error includes all errors except a quantization error, and is defined as a maximum deviation from the ideal conversion line. Note 2: Conversion time is different in recommended value by power supply voltage. About conversion time, please refer to "Register Configuration". Note 3: Please use input voltage to AIN input Pin in limit of VAREF - VSS. When voltage of range outside is input, conversion value becomes unsettled and gives affect to other channel conversion value. Note 4: Analog Reference Voltage Range: VAREF = VAREF - VSS
Page 119
12. Electrical Characteristics
12.5 AC Characteristics TMP86C845UG
12.5 AC Characteristics
(VSS = 0 V, VDD = 2.7 to 5.5 V, Topr = -40 to 85C) Parameter Symbol Condition NORMAL1, 2 mode Machine cycle time tcy IDLE0, 1, 2 mode SLOW1, 2 mode SLEEP0, 1, 2 mode High level clock pulse width Low level clock pulse width High level clock pulse width Low level clock pulse width tWCH tWCL tWSH tWSL For external clock operation (XIN input) fc = 8 MHz For external clock operation (XTIN input) fs = 32.768 kHz Min 0.5 Typ. - Max 4 s 117.6 - 133.3 Unit
-
62.5
-
ns
-
15.26
-
s
12.6 Recommended Oscillating Conditions
XIN XOUT XTIN XTOUT
C1
C2
C1
C2
(1) High-frequency Oscillation
(2) Low-frequency Oscillation
Note 1: To ensure stable oscillation, the resonator position, load capacitance, etc. must be appropriate. Because these factors are greatly affected by board patterns, please be sure to evaluate operation on the board on which the device will actually be mounted. Note 2: For the resonators to be used with Toshiba microcontrollers, we recommend ceramic resonators manufactured by Murata Manufacturing Co., Ltd. For details, please visit the website of Murata at the following URL: http://www.murata.co.jp
Page 120
TMP86C845UG
12.7 Handling Precaution
- The solderability test conditions for lead-free products (indicated by the suffix G in product name) are shown below. 1. When using the Sn-37Pb solder bath Solder bath temperature = 230 C Dipping time = 5 seconds Number of times = once R-type flux used 2. When using the Sn-3.0Ag-0.5Cu solder bath Solder bath temperature = 245 C Dipping time = 5 seconds Number of times = once R-type flux used Note: The pass criteron of the above test is as follows: Solderability rate until forming 95 % - When using the device (oscillator) in places exposed to high electric fields such as cathode-ray tubes, we recommend electrically shielding the package in order to maintain normal operating condition.
Page 121
12. Electrical Characteristics
12.6 Recommended Oscillating Conditions TMP86C845UG
Page 122
TMP86C845UG
13. Package Dimension
P-LQFP44-1010-0.80A
Unit: mm
Page 123
13. Package Dimension
TMP86C845UG
Page 124
This is a technical document that describes the operating functions and electrical specifications of the 8-bit microcontroller series TLCS-870/C (LSI). Toshiba provides a variety of development tools and basic software to enable efficient software development. These development tools have specifications that support advances in microcomputer hardware (LSI) and can be used extensively. Both the hardware and software are supported continuously with version updates. The recent advances in CMOS LSI production technology have been phenomenal and microcomputer systems for LSI design are constantly being improved. The products described in this document may also be revised in the future. Be sure to check the latest specifications before using. Toshiba is developing highly integrated, high-performance microcomputers using advanced MOS production technology and especially well proven CMOS technology. We are prepared to meet the requests for custom packaging for a variety of application areas. We are confident that our products can satisfy your application needs now and in the future.


▲Up To Search▲   

 
Price & Availability of TMP86C845UG

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X